Cited 18 times in
Load-Bearing Capacity of Posterior CAD/CAM Implant-Supported Fixed Partial Dentures Fabricated with Different Esthetic Materials
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김종은 | - |
dc.contributor.author | 우창우 | - |
dc.contributor.author | 이근우 | - |
dc.date.accessioned | 2019-12-18T00:33:38Z | - |
dc.date.available | 2019-12-18T00:33:38Z | - |
dc.date.issued | 2019 | - |
dc.identifier.issn | 0893-2174 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/173106 | - |
dc.description.abstract | PURPOSE: To compare the load-bearing capacity after long-term use (5-year simulation) of posterior three-unit implant-supported fixed partial dentures (FPDs) fabricated with different esthetic materials. MATERIALS AND METHODS: A total of 20 specimens fabricated from one design file using CAD/CAM were divided into four groups: polyetherketoneketone (PEKK) veneered with composite resin (CR); PEKK veneered with lithium disilicate (LD); zirconia veneered with fluorapatite (FA); and monolithic zirconia. Samples were placed into a chewing simulator with simultaneous thermocycling. The fracture load after aging was measured using the universal testing machine with load on the central fossa of the pontic. RESULTS: FPDs fabricated with PEKK + LD had significantly higher fracture load (1,526.56 [SD 95.54] N) compared to PEKK + CR (1,069.54 [SD 67.94] N) (P < .05). FPDs fabricated with zirconia materials had significantly higher fracture load compared to PEKK materials (P < .05). There was no significant difference between monolithic zirconia and zirconia + FA (P > .05). CONCLUSION: FPDs fabricated with PEKK + LD were superior to PEKK + CR. These materials can be promising alternatives for use as implant-supported FPD materials in the high-stress-bearing posterior region. Zirconia + FA can be an alternative to monolithic zirconia in cases that require more esthetics. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | Quintessence Pub. Co. | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF PROSTHODONTICS | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.subject.MESH | Computer-Aided Design | - |
dc.subject.MESH | Dental Porcelain | - |
dc.subject.MESH | Dental Restoration Failure | - |
dc.subject.MESH | Dental Stress Analysis | - |
dc.subject.MESH | Denture, Partial, Fixed* | - |
dc.subject.MESH | Esthetics, Dental* | - |
dc.subject.MESH | Materials Testing | - |
dc.subject.MESH | Weight-Bearing | - |
dc.subject.MESH | Zirconium | - |
dc.title | Load-Bearing Capacity of Posterior CAD/CAM Implant-Supported Fixed Partial Dentures Fabricated with Different Esthetic Materials | - |
dc.type | Article | - |
dc.contributor.college | College of Dentistry (치과대학) | - |
dc.contributor.department | Dept. of Prosthodontics (보철과학교실) | - |
dc.contributor.googleauthor | Ami Amelya | - |
dc.contributor.googleauthor | Jong-Eun Kim | - |
dc.contributor.googleauthor | Chang-Woo Woo | - |
dc.contributor.googleauthor | Jamiyandorj Otgonbold | - |
dc.contributor.googleauthor | Keun-Woo Lee | - |
dc.identifier.doi | 10.11607/ijp.6128 | - |
dc.contributor.localId | A00927 | - |
dc.contributor.localId | A05155 | - |
dc.contributor.localId | A02688 | - |
dc.relation.journalcode | J01153 | - |
dc.identifier.eissn | 1942-4426 | - |
dc.identifier.pmid | 30856647 | - |
dc.identifier.url | http://quintpub.com/journals/ijp/abstract.php?iss2_id=1594&article_id=19255#.XendmuQh2mQ | - |
dc.contributor.alternativeName | Kim, Jong Eun | - |
dc.contributor.affiliatedAuthor | 김종은 | - |
dc.contributor.affiliatedAuthor | 우창우 | - |
dc.contributor.affiliatedAuthor | 이근우 | - |
dc.citation.volume | 32 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 201 | - |
dc.citation.endPage | 204 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF PROSTHODONTICS, Vol.32(2) : 201-204, 2019 | - |
dc.identifier.rimsid | 64282 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.