278 327

Cited 0 times in

4채널 위전도 시스템의 개발 및 유용성

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author이상인-
dc.date.accessioned2019-11-11T07:01:48Z-
dc.date.available2019-11-11T07:01:48Z-
dc.date.issued2000-
dc.identifier.issn1229-0807-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/172483-
dc.description.abstractElectrogastrography(EGG) is a method of measuring gastric electrical activity on the abdomen. Although it is noninvasive and inexpensive. EGG signals have a very low frequency (0.2~10cpm) and extremely low amplitude(10~100㎶). Consequently, its measured waveforms are quite difficult to analyze and it is not completely understood yet. In this study, a four-channel EGG measurement system with Running Spectrum Analysis was built to measure and analyze the action potentials of the stomach. This System was compared with the commercially available one-channel Digitrapper EGG. The percentages of 3 cpm were compared with the best channel of the four-channel system and channel 1, whose electrode position was approximately the same as that of the commercially available one-channel system for normal subjects. The respectively, and it was statistically significant(p<0.001). The average 3 cpm percentages of the best channel and channel 1 for postprandial measurement were 90.4% and 76.5%, respectively, and it was also statistically significant(p<0.001). From these results. it was confirmed that a 4-channel EGG system is better than a 1-channel one for EGG measurement.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisherThe Korea Society of Medical and Biological Engineering-
dc.relation.isPartOfJournal of Biomedical Engineering Research (의공학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title4채널 위전도 시스템의 개발 및 유용성-
dc.title.alternativeDevelopment of a 4 Channel EGG System and Its Usefulness-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthor유창용-
dc.contributor.googleauthor이상인-
dc.contributor.googleauthor남기창-
dc.contributor.googleauthor송철규-
dc.contributor.googleauthor김덕원-
dc.contributor.localIdA00376-
dc.contributor.localIdA02828-
dc.relation.journalcodeJ01263-
dc.subject.keywordThe percentage of 3 cpm-
dc.subject.keywordFour-channel EGG-
dc.subject.keywordRunning spectrum analysis(RSA)-
dc.subject.keywordRelative electrode position-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.affiliatedAuthor김덕원-
dc.contributor.affiliatedAuthor이상인-
dc.citation.volume21-
dc.citation.number6-
dc.citation.startPage543-
dc.citation.endPage550-
dc.identifier.bibliographicCitationJournal of Biomedical Engineering Research (의공학회지), Vol.21(6) : 543-550, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.