326 468

Cited 0 times in

3가지 인공누액 점안 후 점탄성에 의한 눈물층 분포 비교

DC Field Value Language
dc.contributor.author김응권-
dc.date.accessioned2019-11-11T05:53:23Z-
dc.date.available2019-11-11T05:53:23Z-
dc.date.issued2000-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/172241-
dc.description.abstractWe intended to evaluate the viscosity-dependent distribution of tear film after dropping of three artificial tears with different viscosity. We measured the corneal thickness including tear film thickness after dropping of Optagent[Povidon iodide 2%; viscosity: 1.5millimeter2/sec], Tears naturale free[hydroxypropyl methylcellulose 0.3%, dextran 0.1%;6.4 millimeter2/sec], Lacura [sodium hyaluronate 0.1%;4.6 millimeter2/sec]in 12 adult men and women without dry eye by optical beam scanning differential pachymetry of Orbscan topography. 1 minute after dropping, the thickness of 3 millimeter superior and inferior to center of cornea increased respectively 4.1 +/-0.4 micrometer, 0.4 +/-0.1micrometer[p=0.014]in Optagent, 2.4 +/-0.3 micrometer, 2.3 +/-0.2 micrometer[p=0.425]in Tears naturale free and 2.5 +/-0.5 micrometer, 2.0 +/-0.2 micrometer[p=0.126]in Lacure. 10 minute after dropping, the thickness of 3 millimeter superior and inferior to center of cornea increased respectively 2.7 +/-0.3 micrometer, 0.3 +/-0.1 micrometer[p=0.025]in Optagent, 1.7 +/-0.2 micrometer, 1.6 +/-0.2 micrometer[p=0.326]in Tears naturale free and 1.4 +/-0 .4 micrometer, 1.2 +/-0.2 micrometer[p=0.237]in Lacura. In conclusion, the artificial tears with relatively high viscosity dstributed evenly along the corneal surface after dropping, but those with relatively low viscosity distributed mainly superior to center of cornea with statistical significance. So when treating of corneal lesion in dry eye, we think that artificial tears with proper viscosity will be needed according to the location of the lesion.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJournal of the Korean Ophthalmological Society (대한안과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.title3가지 인공누액 점안 후 점탄성에 의한 눈물층 분포 비교-
dc.title.alternativeThe Comparison of Viscosity -dependent Distribution of Tear Film after Dropping of Three Artificial Tears-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthor현준일-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor이재범-
dc.contributor.localIdA00831-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordArtificial tear-
dc.subject.keywordDry eye-
dc.subject.keywordTear film thickness-
dc.subject.keywordViscosity-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.affiliatedAuthor김응권-
dc.citation.volume41-
dc.citation.number3-
dc.citation.startPage607-
dc.citation.endPage612-
dc.identifier.bibliographicCitationJournal of the Korean Ophthalmological Society (대한안과학회지), Vol.41(3) : 607-612, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.