233 310

Cited 3 times in

Usefulness of a developed four-channel EGG system with running spectrum analysis

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author이상인-
dc.date.accessioned2019-11-11T05:31:18Z-
dc.date.available2019-11-11T05:31:18Z-
dc.date.issued2000-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/171941-
dc.description.abstractElectrogastrography (EGG) is a method of measuring action potentials on the abdomen. It is noninvasive, inexpensive and easy to measure. However, the EGG signal has a very low frequency (0.05 Hz) and an extremely low amplitude (10-100 microV). Consequently, its measured waveform is difficult to analyze and it is not yet completely understood. In this study, a four-channel EGG measurement system was built to measure the action potential of the stomach. This system was compared with the commercially available one-channel Digitrapper EGG. The 3 cpm percentages were compared between the best channel of the four-channel system and channel 1, whose electrode position was similar to the commercially available one-channel system for normal subjects. The average 3 cpm percentage of the best channel and channel 1 for preprandial measurement was 89.5% and 83.2%, respectively, and this was statistically significant (p < 0.001). Also the average 3 cpm percentage of the best channel and channel 1 for postprandial measurement was 90.4% and 76.5%, respectively, and this was statistically significant (p = 0.003). From these results, it can be concluded that a multi-channel EGG system is required for better EGG measurement.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYonsei Medical Journal-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.subject.MESHAction Potentials*-
dc.subject.MESHAdult-
dc.subject.MESHHumans-
dc.subject.MESHStomach/physiology*-
dc.titleUsefulness of a developed four-channel EGG system with running spectrum analysis-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthorDeok Won Kim-
dc.contributor.googleauthorChang Yong Ryu-
dc.contributor.googleauthorSang In Lee-
dc.identifier.doi10.3349/ymj.2000.41.2.230-
dc.contributor.localIdA00376-
dc.contributor.localIdA02828-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid10807025-
dc.subject.keywordElectrogastrography-
dc.subject.keywordfour-channel EGG-
dc.subject.keywordpre- and postprandial-
dc.subject.keywordelectrode placement-
dc.subject.keywordrunning spectrum-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.affiliatedAuthor김덕원-
dc.contributor.affiliatedAuthor이상인-
dc.citation.volume41-
dc.citation.number2-
dc.citation.startPage230-
dc.citation.endPage236-
dc.identifier.bibliographicCitationYonsei Medical Journal, Vol.41(2) : 230-236, 2000-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.