Abstract
BACKGROUND: There are concerns regarding local toxicity when IORT is applied in Asian women with a smaller breast volume than that of Western women. Trials are required to develop safety profiles for this technique. The aim of this trial was to evaluate acute toxicity after intra-operative radiotherapy (IORT) with low-energy X-ray plus whole breast irradiation (WBI) in Asian patients with breast cancer.

METHODS: This single-arm, single-institute, phase II trial investigated acute toxicity after completion of radiotherapy (targeted IORT followed by WBI) in Korean patients treated with breast-conserving surgery (BCS). In the conventional WBI arm from the TARGIT-A trial, the incidence of acute toxicity within 6 months was 15%. To prove the non-inferiority of the acute toxicity rate, 215 patients were required. This trial is registered with ClinicalTrials.gov (NCT02213991).

RESULTS: Two-hundred and fifteen women were enrolled, and 198 underwent IORT. In 33 patients, clinically significant complications during the acute period were noted. The incidence of acute toxicity was 16.7% (95% CI 11.5-21.9%). There were 29 patients with seroma needing more than 3 aspirations, 4 with wound infection, and 2 with skin breakdown. There was no difference in the rate of complications according to the tumor volume or the tumor-breast volume ratio. Advanced age and high BMI were risk factors for acute complications.

CONCLUSIONS: Targeted intra-operative radiotherapy using Intrabeam® is a safe procedure for Korean patients with breast cancer with an acceptable toxicity profile in the acute period.
Full Text
https://link.springer.com/article/10.1007%2Fs10549-018-5038-x
DOI
10.1007/s10549-018-5038-x
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Surgery (외과학교실) > 1. Journal Papers
Yonsei Authors
Kim, Jun Won(김준원) ORCID logo https://orcid.org/0000-0003-1358-364X
Bae, Soong June(배숭준) ORCID logo https://orcid.org/0000-0002-0012-9694
Ahn, Sung Gwe(안성귀) ORCID logo https://orcid.org/0000-0002-8778-9686
Yoon, Changik(윤창익)
Lee, Ik Jae(이익재) ORCID logo https://orcid.org/0000-0001-7165-3373
Lee, Hak Woo(이학우)
Jeong, Joon(정준) ORCID logo https://orcid.org/0000-0003-0397-0005
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/169970
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links