비장티푸스성 살모넬라균에 의한 심율동전환제세동기 삽입부 감염 1예
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이동준 | - |
dc.contributor.author | 이승현 | - |
dc.contributor.author | 한재현 | - |
dc.date.accessioned | 2018-11-26T05:57:01Z | - |
dc.date.available | 2018-11-26T05:57:01Z | - |
dc.date.issued | 2013 | - |
dc.identifier.issn | 1738-9364 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/165831 | - |
dc.description.abstract | Non-typhoidal salmonella is rarely the cause of pacemaker infection. A 68-year-old man was referred to our hospital with tenderness and swelling at his cardiac resynchronization therapy defibrillator (CRT-D) implantation site. He had undergone CRT-D implantation because of sustained ventricular tachycardia and heart failure 7 years earlier, and the generator had been changed 2 months earlier. Twenty-four years earlier, he had undergone aortic valve replacement and mitral valve repair. We removed the generator and all of the CRT-D leads. After lead extraction, non-typhoidal salmonella serogroup B was cultured at the pocket and lead tip. The patient was managed successfully with lead extraction and antibiotic therapy. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.language | Korean | - |
dc.publisher | 대한내과학회 | - |
dc.relation.isPartOf | Korean Journal of Medicine | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 비장티푸스성 살모넬라균에 의한 심율동전환제세동기 삽입부 감염 1예 | - |
dc.title.alternative | Cardiac Resynchronization Therapy-Defibrillator Pocket Infection Due to Non-Typhoidal Salmonella Infection | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Internal Medicine (내과학교실) | - |
dc.contributor.googleauthor | 이동준 | - |
dc.contributor.googleauthor | 이승현 | - |
dc.contributor.googleauthor | 한재현 | - |
dc.contributor.googleauthor | 이승준 | - |
dc.contributor.googleauthor | 박희남 | - |
dc.contributor.googleauthor | 이문형 | - |
dc.contributor.googleauthor | 정보영 | - |
dc.identifier.doi | 10.3904/kjm.2013.84.3.418 | - |
dc.contributor.localId | A02733 | - |
dc.contributor.localId | A02932 | - |
dc.contributor.localId | A04320 | - |
dc.relation.journalcode | J02059 | - |
dc.subject.keyword | Cardiac resynchronization therapy device | - |
dc.subject.keyword | Infection | - |
dc.subject.keyword | Salmonella | - |
dc.subject.keyword | Lead extraction | - |
dc.contributor.alternativeName | Lee, Dong Jun | - |
dc.contributor.affiliatedAuthor | 이동준 | - |
dc.contributor.affiliatedAuthor | 이승현 | - |
dc.contributor.affiliatedAuthor | 한재현 | - |
dc.citation.volume | 84 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 418 | - |
dc.citation.endPage | 422 | - |
dc.identifier.bibliographicCitation | Korean Journal of Medicine, Vol.84(3) : 418-422, 2013 | - |