386 767

Cited 12 times in

Biomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes

DC Field Value Language
dc.contributor.author강성용-
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author이훈-
dc.date.accessioned2018-11-05T16:40:58Z-
dc.date.available2018-11-05T16:40:58Z-
dc.date.issued2018-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/165047-
dc.description.abstractPURPOSE: To investigate biomechanical properties of the cornea using a dynamic Scheimpflug analyzer according to age. MATERIALS AND METHODS: In this prospective, cross-sectional, observational study, participants underwent ophthalmic investigations including corneal biomechanical properties, keratometric values, intraocular pressure (IOP), and manifest refraction spherical equivalent (MRSE). We determined the relationship of biomechanical parameters and ocular/systemic variables (participant's age, MRSE, IOP, and mean keratometric values) by piecewise regression analysis, association of biomechanical parameters with variables by Spearman's correlation and stepwise multiple regression analyses, and reference intervals (RI) by the bootstrap method. RESULTS: This study included 217 eyes of 118 participants (20-81 years of age). Piecewise regression analysis between Corvis-central corneal thickness (CCT) and participant's age revealed that the optimal cut-off value of age was 45 years. No clear breakpoints were detected between the corneal biomechanical parameters and MRSE, IOP, and mean keratometric values. Corneal velocity, deformation amplitude, radius, maximal concave power, Corvis-CCT, and Corvis-IOP exhibited correlations with IOP, regardless of age (all ages, 20-44 years, and over 44 years). With smaller deformation amplitude and corneal velocity as well as increased Corvis-IOP and Corvis-CCT, IOP became significantly increased. We provided the results of determination of confidence interval from RI data using bootstrap method in three separate age groups (all ages, 20-44 years, and over 44 years). CONCLUSION: We demonstrated multiple corneal biomechanical parameters according to age, and reported that the corneal biomechanical parameters are influenced by IOP.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageEnglish-
dc.publisherYonsei University-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleBiomechanical Properties of the Cornea Using a Dynamic Scheimpflug Analyzer in Healthy Eyes-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthorHun Lee-
dc.contributor.googleauthorDavid Sung Yong Kang-
dc.contributor.googleauthorByoung Jin Ha-
dc.contributor.googleauthorJin Young Choi-
dc.contributor.googleauthorEung Kweon Kim-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorTae-im Kim-
dc.identifier.doi10.3349/ymj.2018.59.9.1115-
dc.contributor.localIdA00040-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03344-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid30328327-
dc.subject.keywordCorneal biomechanical property-
dc.subject.keywordage-
dc.subject.keyworddynamic Scheimpflug analyzer-
dc.subject.keywordhealthy adult population-
dc.contributor.alternativeNameKang, Sung Yong-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameLee, Hun-
dc.contributor.affiliatedAuthor강성용-
dc.contributor.affiliatedAuthor김응권-
dc.contributor.affiliatedAuthor김태임-
dc.contributor.affiliatedAuthor서경률-
dc.contributor.affiliatedAuthor이훈-
dc.citation.volume59-
dc.citation.number9-
dc.citation.startPage1115-
dc.citation.endPage1122-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.59(9) : 1115-1122, 2018-
dc.identifier.rimsid58605-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.