Cited 44 times in
Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.contributor.author | 서경률 | - |
dc.date.accessioned | 2018-08-28T17:28:31Z | - |
dc.date.available | 2018-08-28T17:28:31Z | - |
dc.date.issued | 2018 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/162655 | - |
dc.description.abstract | BACKGROUND: To evaluate clinical factors affecting postoperative vaulting in eyes that had achieved optimal vaulting within the range of 250-750 mum following implantation of 12.6-mm V4c implantable collamer lenses (ICL). METHODS: A total of 236 eyes of 236 patients that had achieved optimal vaulting following implantation of a 12.6-mm V4c ICL were retrospectively analyzed. Associations between postoperative vaulting and age, preoperative anterior chamber depth (ACD), preoperative axial length (AL), preoperative white-to-white diameter, preoperative pupil size, preoperative sulcus-to-sulcus diameter, and preoperative manifest refraction spherical equivalent were investigated using simple regression, stepwise multiple regression, and multinomial logistic regression analyses. RESULTS: Mean central vaulting at the 6-month follow-up was 519.0 +/- 112.8 mum. Variables relevant to postoperative vaulting were, in order of influence, preoperative ACD (beta = 0.305, p < 0.001), preoperative pupil size (beta = 0.218, p < 0.001), and preoperative AL (beta = 0.171, p = 0.006). Low preoperative pupil size was associated with low optimal vaulting (250 to 450 mum), relative to that observed in the mid optimal vaulting group (451 to 550 mum) (odds ratio = 0.532, P = 0.021). Increasing preoperative ACD was associated with high optimal vaulting (551 and 750 mum), relative to that observed the mid optimal vaulting group (odds ratio = 6.340, P = 0.034). CONCLUSIONS: Myopic eyes with greater preoperative ACD, larger pupil size, and longer AL are predisposed to higher postoperative vaulting following 12.6-mm V4c ICL implantation. Therefore, the extremes of these parameters should be considered when choosing V4c ICL size. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | English | - |
dc.publisher | BioMed Central | - |
dc.relation.isPartOf | BMC OPHTHALMOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Follow-Up Studies | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Intraocular/*methods Lens Implantation | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Myopia/physiopathology/*surgery | - |
dc.subject.MESH | *Phakic Intraocular Lenses | - |
dc.subject.MESH | Prosthesis Design | - |
dc.subject.MESH | Ocular *Refraction | - |
dc.subject.MESH | Retrospective Studies | - |
dc.subject.MESH | Treatment Outcome | - |
dc.subject.MESH | Visual Acuity | - |
dc.subject.MESH | Young Adult | - |
dc.title | Analysis of pre-operative factors affecting range of optimal vaulting after implantation of 12.6-mm V4c implantable collamer lens in myopic eyes | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Ophthalmology | - |
dc.contributor.googleauthor | Hun Lee | - |
dc.contributor.googleauthor | David Sung Yong Kang | - |
dc.contributor.googleauthor | Jin Young Choi | - |
dc.contributor.googleauthor | Byoung Jin Ha | - |
dc.contributor.googleauthor | Eung Kweon Kim | - |
dc.contributor.googleauthor | Kyoung Yul Seo | - |
dc.contributor.googleauthor | Tae-Im Kim | - |
dc.identifier.doi | 10.1186/s12886-018-0835-x | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A01870 | - |
dc.relation.journalcode | J00370 | - |
dc.identifier.eissn | 1471-2415 | - |
dc.identifier.pmid | 29980187 | - |
dc.subject.keyword | 12.6-mm V4c implantable collamer lenses | - |
dc.subject.keyword | Anterior chamber depth | - |
dc.subject.keyword | Axial length | - |
dc.subject.keyword | Postoperative vaulting | - |
dc.subject.keyword | Preoperative pupil size | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.alternativeName | Seo, Kyuong Yul | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Seo, Kyuong Yul | - |
dc.citation.volume | 18 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 163 | - |
dc.identifier.bibliographicCitation | BMC OPHTHALMOLOGY, Vol.18(1) : 163, 2018 | - |
dc.identifier.rimsid | 60234 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.