Utility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery

DC Field Value Language
dc.contributor.author김찬윤-
dc.contributor.author배형원-
dc.contributor.author성공제-
dc.contributor.author이상엽-
dc.date.accessioned2018-08-28T16:55:23Z-
dc.date.available2018-08-28T16:55:23Z-
dc.date.issued2018-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/162071-
dc.description.abstractThe utility of Goldmann applanation tonometry (GAT) for monitoring intraocular pressure (IOP) in open-angle glaucoma (OAG) patients with a history of laser refractive surgery was investigated by comparing IOP fluctuations measured using GAT and dynamic contour tonometry (DCT) on the same day. In this retrospective study, patients were divided into one of two subgroups according to IOP fluctuation values using GAT: 43 eyes in the low IOP fluctuation group (LIFG [GAT fluctuation </=1.7 mmHg]); and 55 eyes in the high IOP fluctuation group (HIFG [GAT fluctuation >1.7 mmHg]). IOP fluctuation was defined as the standard deviation of all IOP values during follow-up. IOP parameters using GAT were compared with those of DCT. Correlation analyses were performed among IOP parameters, and between IOP fluctuation and associated factors including central corneal thickness, corneal curvature, and axial length. All IOP parameters demonstrated significantly high values in the HIFG compared with those in the LIFG. Mean and peak IOP using DCT were significantly higher than those using GAT in both groups. However, there were no significant differences in IOP fluctuation and reduction using both tonometry methods in the HIFG (p = 0.946 and p = 0.986, respectively). Bland-Altman analysis revealed similar fluctuations using GAT and DCT. In multivariate analyses, there was a significant correlation between fluctuations using GAT and DCT in the HIFG (p = 0.043). These results suggest that IOP monitoring using GAT is a reliable method of monitoring IOP change in glaucoma patients with a history of laser refractive surgery, especially those exhibiting high IOP fluctuation. Nevertheless, several factors, including central corneal thickness, corneal curvature, and axial length, should be considered when using GAT for IOP monitoring.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherPublic Library of Science-
dc.relation.isPartOfPLOS ONE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHFemale-
dc.subject.MESHOpen-Angle/*physiopathology/surgery Glaucoma-
dc.subject.MESHHumans-
dc.subject.MESH*Intraocular Pressure-
dc.subject.MESHSubepithelial *Keratectomy, Laser-Assisted-
dc.subject.MESHLaser In Situ *Keratomileusis-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOcular/*utilization Tonometry-
dc.titleUtility of Goldmann applanation tonometry for monitoring intraocular pressure in glaucoma patients with a history of laser refractory surgery-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Ophthalmology-
dc.contributor.googleauthorSang Yeop Lee-
dc.contributor.googleauthorHyoung Won Bae-
dc.contributor.googleauthorHee Jung Kwon-
dc.contributor.googleauthorGong Je Seong-
dc.contributor.googleauthorChan Yun Kim-
dc.identifier.doi10.1371/journal.pone.0192344-
dc.contributor.localIdA01035-
dc.contributor.localIdA01814-
dc.contributor.localIdA01946-
dc.contributor.localIdA02820-
dc.relation.journalcodeJ02540-
dc.identifier.eissn1932-6203-
dc.identifier.pmid29401477-
dc.contributor.alternativeNameKim, Chan Yun-
dc.contributor.alternativeNameBae, Hyoung Won-
dc.contributor.alternativeNameSeong, Gong Je-
dc.contributor.alternativeNameLee, Sang Yeop-
dc.contributor.affiliatedAuthorKim, Chan Yun-
dc.contributor.affiliatedAuthorBae, Hyoung Won-
dc.contributor.affiliatedAuthorSeong, Gong Je-
dc.contributor.affiliatedAuthorLee, Sang Yeop-
dc.citation.volume13-
dc.citation.number2-
dc.citation.startPagee0192344-
dc.identifier.bibliographicCitationPLOS ONE, Vol.13(2) : e0192344, 2018-
dc.identifier.rimsid59661-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.