500 610

Cited 16 times in

Different Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers

DC Field Value Language
dc.contributor.author김선일-
dc.contributor.author김의성-
dc.contributor.author박정원-
dc.contributor.author신수정-
dc.date.accessioned2018-08-28T16:43:36Z-
dc.date.available2018-08-28T16:43:36Z-
dc.date.issued2018-
dc.identifier.issn0161-0457-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/161875-
dc.description.abstractObjective: To investigate the effect of different setting conditions on surface microhardness and setting properties of calcium silicate-based sealers. Methods: Three sealers, EndoSequence Bioceramic (BC; Brasseler USA, Savannah, GA, USA), Endoseal MTA (ES; Maruchi, Wonju, Korea), and Well-Root ST (WR; Vericom, Chuncheon, Korea), were compared. Specimens were exposed to either butyric acid (pH 5.4) or phosphate-buffered saline (PBS [pH 7.4]) for 48 h and stored at 100% humidity for 12 days. The control specimens were stored at 100% humidity for 14 days. Surface microhardness was measured, topographic changes were observed, and phase analysis was performed using X-ray diffraction. Microhardness according to storage conditions was compared using one-way analysis of variance and Tukey's multiple comparison tests (P < .05). Results: The BC and ES sealers exhibited decreased microhardness when stored in acid or PBS compared with control (P < .05). In the WR group, acid exposure lowered microhardness of the specimens compared with control (P < .05). Scanning electron microscopy revealed different topographies in specimens from all tested sealers exposed to acid or PBS. Conclusion: The surface microhardness of calcium silicate-based sealers was reduced by exposure to either acid or PBS. Acid solutions, however, had a more detrimental effect than PBS.-
dc.description.statementOfResponsibilityopen-
dc.languageEnglish-
dc.publisherJohn Wiley & Sons-
dc.relation.isPartOfSCANNING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleDifferent Setting Conditions Affect Surface Characteristics and Microhardness of Calcium Silicate-Based Sealers-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry-
dc.contributor.departmentDept. of Conservative Dentistry-
dc.contributor.googleauthorDong-Kyu Yang-
dc.contributor.googleauthorSunil Kim-
dc.contributor.googleauthorJeong-Won Park-
dc.contributor.googleauthorEuiseong Kim-
dc.contributor.googleauthorSu-Jung Shin-
dc.identifier.doi10.1155/2018/7136345-
dc.contributor.localIdA00556-
dc.contributor.localIdA00833-
dc.contributor.localIdA01649-
dc.contributor.localIdA02117-
dc.relation.journalcodeJ02638-
dc.identifier.eissn1932-8745-
dc.identifier.pmid29576841-
dc.contributor.alternativeNameKim, Sun Il-
dc.contributor.alternativeNameKim, Eui Seong-
dc.contributor.alternativeNamePark, Jeong Won-
dc.contributor.alternativeNameShin, Su Jung-
dc.contributor.affiliatedAuthorKim, Sun Il-
dc.contributor.affiliatedAuthorKim, Eui Seong-
dc.contributor.affiliatedAuthorPark, Jeong Won-
dc.contributor.affiliatedAuthorShin, Su Jung-
dc.citation.volume2018-
dc.citation.startPage7136345-
dc.identifier.bibliographicCitationSCANNING, Vol.2018 : 7136345, 2018-
dc.identifier.rimsid59467-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Conservative Dentistry (보존과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.