5 16

Cited 0 times in

Inter- and Intra-Observer Variability of the Volume of Cervical Ossification of the Posterior Longitudinal Ligament Using Medical Image Processing Software

Authors
 Dong Ah Shin  ;  Gyu Yeul Ji  ;  Chang Hyun Oh  ;  Keung Nyun Kim  ;  Do Heum Yoon  ;  Hyunchul Shin 
Citation
 Journal of Korean Neurosurgical Society, Vol.60(4) : 441-447, 2017 
Journal Title
 Journal of Korean Neurosurgical Society 
ISSN
 2005-3711 
Issue Date
2017
Keywords
3D analysis ; MIMICS ; Ossification ; Posterior longitudinal ligament ; Volume
Abstract
OBJECTIVE: Computed tomography (CT)-based method of three dimensional (3D) analysis (MIMICS®, Materialise, Leuven, Belgium) is reported as very useful software for evaluation of OPLL, but its reliability and reproducibility are obscure. This study was conducted to evaluate the accuracy of MIMICS® system, and inter- and intra-observer reliability in the measurement of OPLL. METHODS: Three neurosurgeons independently analyzed the randomly selected 10 OPLL cases with medical image processing software (MIMICS®) which create 3D model with Digital Imaging and Communication in Medicine (DICOM) data from CT images after brief explanation was given to examiners before the image construction steps. To assess the reliability of inter- and intra-examiner intraclass correlation coefficient (ICC), 3 examiners measured 4 parameters (volume, length, width, and length) in 10 cases 2 times with 1-week interval. RESULTS: The inter-examiner ICCs among 3 examiners were 0.996 (95% confidence interval [CI], 0.987-0.999) for volume measurement, 0.973 (95% CI, 0.907-0.978) for thickness, 0.969 (95% CI, 0.895-0.993) for width, and 0.995 (95% CI, 0.983-0.999) for length. The intra-examiner ICCs were 0.994 (range, 0.991-0.996) for volume, 0.996 (range, 0.944-0.998) for length, 0.930 (range, 0.873-0.947) for width, and 0.987 (range, 0.985-0.995) for length. CONCLUSION: The medical image processing software (MIMICS®) provided detailed quantification OPLL volume with minimal error of inter- and intra-observer reliability in the measurement of OPLL.
URI
http://ir.ymlib.yonsei.ac.kr/handle/22282913/161676
DOI
10.3340/jkns.2015.0708.014
Appears in Collections:
1. Journal Papers (연구논문) > 1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실)
Yonsei Authors
김긍년(Kim, Keung Nyun) ; 신동아(Shin, Dong A) ; 윤도흠(Yoon, Do Heum)
사서에게 알리기
  feedback
Files in This Item:
T201705524.pdf Download
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse