Status of hypertension screening in the Korea National General Health Screening Program: a questionnaire survey on 210 screening centers in two metropolitan areas.

Authors
 Seung Won Lee  ;  Hae-Young Lee  ;  Sang Hyun Ihm  ;  Sung Ha Park  ;  Tae Hyun Kim  ;  Hyeon Chang Kim 
Citation
 Clinical Hypertension, Vol.23 : 23-28, 2017 
Journal Title
Clinical Hypertension
Issue Date
2017
Keywords
Blood pressure ; Hypertension ; Quality control ; Screening ; Sphygmomanometer
Abstract
Background:

The purpose of this survey was to evaluate the performance of hypertension screening in medical institutions conducting the national general health screening program of the Republic of Korea.

Methods:

We contacted 700 medical institutions of Seoul and Incheon areas which performed the national general health screening program in 2016, and 210 of them completed telephone survey. The questions asked in the survey include equipment, environment, personnel and quality control procedures for blood pressure (BP) measurement, and interpretation of the measurements.

Results:

A majority of the responding screening centers used oscilloscope sphygmomanometers (51.9%), had only one-sized cuff (65.2%), and measured BP in open space (54.3%). BP levels were measured mainly by nurses (62.0%) and doctors (25.0%), after a 1 to10 minutes (84.9%) of resting period. A 75.2% of screening centers regularly calibrated sphygmomanometers, 81.4% had a manual for BP measurement, and 59.0% had a training program. A 80.0% of respondents answered that they used averages of multiple BP measurements to determine an individual's BP level, and 82.9% answered that criteria for hypertension was systolic BP ≥140 mmHg and/or diastolic BP ≥ 90 mmHg. If a screening finds an individual with hypertension, 82.9% of centers recommend revisiting for a second BP measurement rather than start medication immediately.

Conclusion:

In most medical institutions performing general health screening program, certified medical personnel measure BP and interpret the results according to established protocols. However, there is room for improvement in the equipment, environment and quality control procedures for BP measurement.
Files in This Item:
T201705343.pdf Download
DOI
10.1186/s40885-017-0075-z
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers
4. Graduate School of Public Health (보건대학원) > Graduate School of Public Health (보건대학원) > 1. Journal Papers
Yonsei Authors
Kim, Tae Hyun(김태현) ORCID logo https://orcid.org/0000-0003-1053-8958
Kim, Hyeon Chang(김현창) ORCID logo https://orcid.org/0000-0001-7867-1240
Park, Sung Ha(박성하) ORCID logo https://orcid.org/0000-0001-5362-478X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/161629
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links