277 552

Cited 0 times in

생체계측치와 각막 곡률의 차이에 따른 인공수정체 삽입 후 굴절 오차의 경향

DC Field Value Language
dc.contributor.author서경률-
dc.date.accessioned2018-05-10T06:41:17Z-
dc.date.available2018-05-10T06:41:17Z-
dc.date.issued2013-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/158434-
dc.description.abstractPurpose: The purpose of this study was to investigate the error tendency between preoperative expected refraction and postoperative manifest refraction based on axial length, anterior chamber depth, and keratometric data obtained by an automated keratometer and Pentacam® in cataract surgery cases and to report how their differences affect determination of intraocular lens (IOL) power. Methods: The authors retrospectively reviewed the medical records of 110 eyes of 84 patients who underwent cataract surgery. Axial length and anterior chamber depth were measured by A scan ultrasound biometry, while keratometric values were obtained by an automated keratometer and Pentacam®. IOL power was calculated using the SRK/T formula. Patients were divided into 3 groups based on the axial length, anterior chamber depth, and the difference of keratometric values between the 2 devices. Refractive error was analyzed 2 months after surgery. Results: There were no statistically significant differences between axial length and anterior chamber depth among the groups; however, the K reading differences were statistically significant. Although the mean absolute error (MAE) of each group showed no statistical significance among the groups, the MAE was more pronounced in the group in which the keratometeric value measured by Pentacam® differed more than 1.00 diopter from the automated keratometer measurements. Conclusions: There was no statistically significant difference between axial length and anterior chamber depth among the groups. A difference of 1.00 diopter or more between the keratometric values obtained by an automated keratometer and Pentacam® significantly affects the postoperative refractive error; therefore, these factors should be considered when determining IOL power.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title생체계측치와 각막 곡률의 차이에 따른 인공수정체 삽입 후 굴절 오차의 경향-
dc.title.alternativeComparison of the Refractive Outcomes According to the Differences of Biometry and Keratometry Reading-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Ophthalmology-
dc.contributor.googleauthor이강훈-
dc.contributor.googleauthor김나래-
dc.contributor.googleauthor서경률-
dc.identifier.doi10.3341/jkos.2013.54.9.1345-
dc.contributor.localIdA01870-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordBiometry-
dc.subject.keywordCataract surgery-
dc.subject.keywordKeratometry reading-
dc.subject.keywordRefractive outcomes-
dc.subject.keywordScheimpflug photography-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.citation.volume54-
dc.citation.number9-
dc.citation.startPage1345-
dc.citation.endPage1352-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.54(9) : 1345-1352, 2013-
dc.identifier.rimsid42433-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.