220 396

Cited 0 times in

Preliminary Experiences of the Combined Midline-Splitting French Door Laminoplasty with Polyether Ether Ketone (PEEK) Plate for Cervical Spondylosis and OPLL.

Authors
 Chang Hyun Oh  ;  Gyu Yeul Ji  ;  Junseok W. Hur  ;  Won-Seok Choi  ;  Dong Ah Shin  ;  Jang-Bo Lee 
Citation
 Korean Journal of Spine, Vol.12(2) : 48-54, 2015 
Journal Title
Korean Journal of Spine
ISSN
 1738-2262 
Issue Date
2015
Keywords
Cervical laminoplasty ; Cervical spondylotic myelopathy ; French-door laminoplasty ; OPLL ; PEEK plate
Abstract
OBJECTIVE: The purpose of this study was to evaluate the safety and efficacy of cervical midline-splitting French-door laminoplasty with a polyether ether ketone (PEEK) plate. The authors retrospectively analyzed the results of patients with cervical laminoplasty miniplate (MAXPACER®) without bone grafts in multilevel cervical stenosis.

METHODS: Fifteen patients (13 males and 2 females, mean age 50.0 years (range 35-72)) with multilevel cervical stenosis (ossification of the posterior longitudinal ligament and cervical spondylotic myelopathy) underwent a combined surgery of midline-splitting French-door laminoplasty with or without mini plate. All 15 patients were followed for at least 12 months (mean follow-up 13.3 months) after surgery, and a retrospective review of the clinical, radiological and surgical data was conducted.

RESULTS: The radiographic results showed a significant increase over the postoperative period in anterior-posterior diameter (9.4±2.2 cm to 16.2±1.1 cm), open angles in cervical lamina (46.5±16.0° to 77.2±13.1°), and sectional volume of cervical central canal (100.5±0.7 cm(2) to 146.5±4.9 cm(2)) (p<0.001). The sagittal alignment of the cervical spine was well preserved (31.7±10.0° to 31.2±7.6°, p=0.877) during the follow-up period. The clinical results were successful, and there were no significant intraoperative complications except for screw displacement in two cases. The mini plate constructs did not fail during the 12 month follow-up period, and the decompression was maintained.

CONCLUSION: Despite the small cohort and short follow-up duration, the present study demonstrated that combined cervical expansive laminoplasty using the mini plate is an effective treatment for multilevel cervical stenosis.
Files in This Item:
T201506125.pdf Download
DOI
10.14245/kjs.2015.12.2.48
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Neurosurgery (신경외과학교실) > 1. Journal Papers
Yonsei Authors
Shin, Dong Ah(신동아) ORCID logo https://orcid.org/0000-0002-5225-4083
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/157262
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links