dc.description.abstract | Purpose : To compare the pupil sizes measured using the automatic pupillometer and pupil card. Methods : We measured pupil sizes using a pupil card (Rosenbaum Card, J.G. Rosenbaum, Cleveland, OH, USA) and automated pupillometer (VIP™-200, Neuroptics Inc., San Clemente, CA, USA) under different luminous intensities in 60 eyes of 60 patients who visited the ophthalmology clinic during August 2013. Results : Under the photopic condition, pupil sizes measured using automated pupillometer were larger than those measured using the pupil card with statistical significance. The 2 techniques were not different under mesopic and scotopic conditions. Under all light conditions, automated pupillometer showed higher inter-rater reliability. Under the scotopic condition, pupil sizes measured using the pupil card were smaller than pupil sizes measured using the pupillometer according to increased pupil size. Conclusions : When compared with pupil card, automated pupillometer provided accurate and reliable measurement with small inter-rater variation and was easy and simple to use. However, based on comparable measurements of both techniques under mesopic and scotopic conditions, the pupil card can be used as preoperative evaluation when considering the cost of purchase and maintenance. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한안과학회 | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Diagnostic Techniques, Ophthalmological/instrumentation* | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Iris/anatomy & histology* | - |
dc.subject.MESH | Light | - |
dc.subject.MESH | Observer Variation | - |
dc.subject.MESH | Pupil/physiology* | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.title | 자동동공측정계와 동공측정표를 이용하여 측정한 동공 크기의 비교 | - |
dc.title.alternative | Comparison of Automatic Pupillometer and Pupil Card for Measuring Pupil Size | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Ophthalmology | - |
dc.contributor.googleauthor | 이택준 | - |
dc.contributor.googleauthor | 김홍석 | - |
dc.contributor.googleauthor | 정지원 | - |
dc.contributor.googleauthor | 이훈 | - |
dc.contributor.googleauthor | 서경률 | - |
dc.contributor.googleauthor | 이형근 | - |
dc.contributor.googleauthor | 김응권 | - |
dc.contributor.googleauthor | 김태임 | - |
dc.identifier.doi | 10.3341/jkos.2015.56.6.863 | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A01870 | - |
dc.contributor.localId | A04790 | - |
dc.contributor.localId | A03303 | - |
dc.contributor.localId | A03344 | - |
dc.contributor.localId | A03736 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.identifier.pmid | 11821211 | - |
dc.subject.keyword | Pupil card | - |
dc.subject.keyword | Pupillometer | - |
dc.subject.keyword | Pupil size | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.alternativeName | Seo, Kyuong Yul | - |
dc.contributor.alternativeName | Lee, Taek June | - |
dc.contributor.alternativeName | Lee, Hyung Keun | - |
dc.contributor.alternativeName | Lee, Hun | - |
dc.contributor.alternativeName | Jung, Ji Won | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Seo, Kyuong Yul | - |
dc.contributor.affiliatedAuthor | Lee, Taek June | - |
dc.contributor.affiliatedAuthor | Lee, Hyung Keun | - |
dc.contributor.affiliatedAuthor | Lee, Hun | - |
dc.contributor.affiliatedAuthor | Jung, Ji Won | - |
dc.citation.volume | 56 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 863 | - |
dc.citation.endPage | 867 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.56(6) : 863-867, 2015 | - |
dc.identifier.rimsid | 41670 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.