Coagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin

DC Field Value Language
dc.contributor.author김희진-
dc.date.accessioned2018-03-26T16:55:00Z-
dc.date.available2018-03-26T16:55:00Z-
dc.date.issued2015-
dc.identifier.issn0268-8921-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/156959-
dc.description.abstractHigh-intensity focused ultrasound (HIFU) can be applied noninvasively to create focused zones of tissue coagulation on various skin layers. We performed a comparative study of HIFU, evaluating patterns of focused tissue coagulation and ablation upon application thereof. A tissue-mimicking (TM) phantom was prepared with bovine serum albumin and polyacrylamide hydrogel to evaluate the geometric patterns of HIFU-induced thermal injury zones (TIZs) for five different HIFU devices. Additionally, for each device, we investigated histologic patterns of HIFU-induced coagulation and ablation in serial sections of cadaveric skin of the face and neck. All HIFU devices generated remarkable TIZs in the TM phantom, with different geometric values of coagulation for each device. Most of the TIZs seemed to be separated into two or more tiny parts. In cadaveric skin, characteristic patterns of HIFU-induced ablation and coagulation were noted along the mid to lower dermis at the focal penetration depth of 3 mm and along subcutaneous fat to the superficial musculoaponeurotic system or the platysma muscle of the neck at 4.5 mm. Additionally, remarkable pre-focal areas of tissue coagulation were observed in the upper and mid dermis at the focal penetration depth of 3 mm and mid to lower dermis at 4.5 mm. For five HIFU devices, we outlined various patterns of HIFU-induced TIZ formation along pre-focal, focal, and post-focal areas of TM phantom and cadaveric skin of the face and neck.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer-
dc.relation.isPartOfLASERS IN MEDICAL SCIENCE-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAged-
dc.subject.MESHAnimals-
dc.subject.MESHCadaver-
dc.subject.MESHCattle-
dc.subject.MESHHigh-Intensity Focused Ultrasound Ablation/adverse effects*-
dc.subject.MESHHigh-Intensity Focused Ultrasound Ablation/instrumentation*-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHPhantoms, Imaging*-
dc.subject.MESHSkin/cytology*-
dc.titleCoagulation and ablation patterns of high-intensity focused ultrasound on a tissue-mimicking phantom and cadaveric skin-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry-
dc.contributor.departmentDept. of Oral Biology-
dc.contributor.googleauthorHee-Jin Kim-
dc.contributor.googleauthorHan Gu Kim-
dc.contributor.googleauthorZhenlong Zheng-
dc.contributor.googleauthorHyoun Jun Park-
dc.contributor.googleauthorJeung Hyun Yoon-
dc.contributor.googleauthorWook Oh-
dc.contributor.googleauthorCheol Woo Lee-
dc.contributor.googleauthorSung Bin Cho-
dc.identifier.doi10.1007/s10103-015-1804-8-
dc.contributor.localIdA01225-
dc.relation.journalcodeJ02158-
dc.identifier.eissn1435-604X-
dc.identifier.pmid26341380-
dc.identifier.urlhttps://link.springer.com/article/10.1007%2Fs10103-015-1804-8-
dc.subject.keywordAblation-
dc.subject.keywordCadaver-
dc.subject.keywordCoagulation-
dc.subject.keywordComparison study-
dc.subject.keywordHigh-intensity focused ultrasound-
dc.subject.keywordTissue phantom-
dc.contributor.alternativeNameKim, Hee Jin-
dc.contributor.affiliatedAuthorKim, Hee Jin-
dc.citation.volume30-
dc.citation.number9-
dc.citation.startPage2251-
dc.citation.endPage2258-
dc.identifier.bibliographicCitationLASERS IN MEDICAL SCIENCE, Vol.30(9) : 2251-2258, 2015-
dc.identifier.rimsid41268-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Oral Biology (구강생물학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.