869 602

Cited 0 times in

컬러콘택트렌즈 기준규격에 관한 국가 간 비교 및 고찰

DC Field Value Language
dc.contributor.author김상아-
dc.contributor.author김응권-
dc.contributor.author김태임-
dc.contributor.author서경률-
dc.contributor.author이형근-
dc.date.accessioned2018-03-26T16:44:26Z-
dc.date.available2018-03-26T16:44:26Z-
dc.date.issued2015-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/156772-
dc.description.abstractPurpose : In this study we investigated the safety level of the national standard for tinted soft contact lenses by comparing the standards in various countries. Methods : To evaluate the current guidelines for tinted soft contact lenses such as form and appearance, diameter, curvature radius, vertex power, cylindrical refractivity and cylindrical axis, luminous/ultraviolet ray (UV) transmittance, moisture content, oxygen permeability coefficient, extractables, elution test, cytotoxicity, sensitization, eye irritation test, acute systemic/subchronic/subacute toxicity, genotoxicity and biocompatibility safety test using rabbit eyes and sterility test. We compared the standards of International Organization for Standardization (ISO), Food and Drug Administration (FDA) of the United States, Ministry of Health, Labor and Welfare (MHLW) of Japan and Ministry of Food and Drug Safety (MFDS) of Korea. Results : The guidelines for tinted soft contact lenses of ISO, FDA and MFDS are similar to soft contact lenses but MHLW of Japan classifies these lenses and sets specific guidelines. First, the oxygen permeability coefficient measured at 6mm from the center should be maintained over 80%. Also, coloring should not affect the oxygen permeability coefficient significantly. Regarding the physical (form and appearance, diameter, curvature radius, moisture content) and optical (vertex power, cylindrical refractivity and cylindrical axis, luminous/UV transmittance, oxygen permeability coefficient) characteristics, no differences were found between ISO and MFDS. However, several differences were found in chemical characteristics (extractables, elution test) and biological stability (cytotoxicity, sensitization, eye irritation test, acute systemic/subchronic/subacute toxicity test, genotoxicity, biocompatibility safety test using rabbit eyes, sterility test). For example, the elution test is required only by MFDS. Conclusions : The reinvestigation into the effectiveness of the elution test is needed and new evaluation measures including scanning electron microscopy and atomic force microscopy designed for tinted soft contact lenses to evaluate the size of the optical area, the location and roughness of the pigmented layer are required.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title컬러콘택트렌즈 기준규격에 관한 국가 간 비교 및 고찰-
dc.title.alternativeComparison and Investigation of the National Standards for Tinted Contact Lenses between Various Countries-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Ophthalmology-
dc.contributor.googleauthor김상아-
dc.contributor.googleauthor정지원-
dc.contributor.googleauthor서경률-
dc.contributor.googleauthor이형근-
dc.contributor.googleauthor김응권-
dc.contributor.googleauthor김태임-
dc.identifier.doi10.3341/jkos.2015.56.11.1692-
dc.contributor.localIdA04525-
dc.contributor.localIdA00831-
dc.contributor.localIdA01080-
dc.contributor.localIdA01870-
dc.contributor.localIdA03303-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordElusion test-
dc.subject.keywordInternational organization for standardization-
dc.subject.keywordMinistry of Food and Drug Safety-
dc.subject.keywordStandard for tinted soft contact lenses-
dc.subject.keywordTinted contact lenses-
dc.contributor.alternativeNameKim, Sang Ah-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameKim, Tae Im-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.alternativeNameLee, Hyung Keun-
dc.contributor.affiliatedAuthorKim, Sang Ah-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorKim, Tae Im-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorLee, Hyung Keun-
dc.citation.volume56-
dc.citation.number11-
dc.citation.startPage1692-
dc.citation.endPage1698-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.56(11) : 1692-1698, 2015-
dc.identifier.rimsid39901-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.