0 478

Cited 11 times in

Binary moving-blocker-based scatter correction in cone-beam computed tomography with width-truncated projections: proof of concept

Authors
 Ho Lee  ;  Benjamin P Fahimian  ;  Lei Xing 
Citation
 PHYSICS IN MEDICINE AND BIOLOGY, Vol.62 : 2176-2193, 2017 
Journal Title
PHYSICS IN MEDICINE AND BIOLOGY
ISSN
 0031-9155 
Issue Date
2017
MeSH
Algorithms ; Artifacts ; Cone-Beam Computed Tomography/instrumentation* ; Cone-Beam Computed Tomography/methods* ; Humans ; Image Processing, Computer-Assisted/methods* ; Pelvis/diagnostic imaging* ; Phantoms, Imaging* ; Rotation ; Scattering, Radiation ; X-Rays
Abstract
This paper proposes a binary moving-blocker (BMB)-based technique for scatter correction in cone-beam computed tomography (CBCT). In concept, a beam blocker consisting of lead strips, mounted in front of the x-ray tube, moves rapidly in and out of the beam during a single gantry rotation. The projections are acquired in alternating phases of blocked and unblocked cone beams, where the blocked phase results in a stripe pattern in the width direction. To derive the scatter map from the blocked projections, 1D B-Spline interpolation/extrapolation is applied by using the detected information in the shaded regions. The scatter map of the unblocked projections is corrected by averaging two scatter maps that correspond to their adjacent blocked projections. The scatter-corrected projections are obtained by subtracting the corresponding scatter maps from the projection data and are utilized to generate the CBCT image by a compressed-sensing (CS)-based iterative reconstruction algorithm. Catphan504 and pelvis phantoms were used to evaluate the method's performance. The proposed BMB-based technique provided an effective method to enhance the image quality by suppressing scatter-induced artifacts, such as ring artifacts around the bowtie area. Compared to CBCT without a blocker, the spatial nonuniformity was reduced from 9.1% to 3.1%. The root-mean-square error of the CT numbers in the regions of interest (ROIs) was reduced from 30.2 HU to 3.8 HU. In addition to high resolution, comparable to that of the benchmark image, the CS-based reconstruction also led to a better contrast-to-noise ratio in seven ROIs. The proposed technique enables complete scatter-corrected CBCT imaging with width-truncated projections and allows reducing the acquisition time to approximately half. This work may have significant implications for image-guided or adaptive radiation therapy, where CBCT is often used.
Full Text
http://iopscience.iop.org/article/10.1088/1361-6560/aa5913
DOI
10.1088/1361-6560/aa5913
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Radiation Oncology (방사선종양학교실) > 1. Journal Papers
Yonsei Authors
Lee, Ho(이호) ORCID logo https://orcid.org/0000-0001-5773-6893
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/154324
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links