Cited 0 times in
임플란트 고정성 보철물 수복을 위한 최소 교합 고경에 대한 고찰
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 강주현 | - |
dc.contributor.author | 차재국 | - |
dc.contributor.author | 최순호 | - |
dc.contributor.author | 김승민 | - |
dc.contributor.author | 박영범 | - |
dc.contributor.author | 송영우 | - |
dc.contributor.author | 이중석 | - |
dc.contributor.author | 정의원 | - |
dc.date.accessioned | 2017-11-02T08:13:30Z | - |
dc.date.available | 2017-11-02T08:13:30Z | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1229-5418 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/154220 | - |
dc.description.abstract | Background: The purpose of this review is to exmanine the minimal interocclusal distance required for implant placement for each implant manufacturer without surgery. Materials and methods: “Minimal interocclusal distance” was defined as the distance from the edentulous alveolar crest to the functional cusp of the opposing teeth or to the contact surface facing the central fossa of implant prosthesis. 15 journals were searched by “Pubmed”, and specifications were inquired by manufacturer. Result: Implants were classified into bone level and soft-tissue level implant. The bone level was divided into external connection type and internal connection type. Implants were categorized into cement-retention type and screw-retention type according to the fastening method of the prosthesis. For the cement-retention type, the bone level implant required 6 mm interocclusal distance and the soft-tissue level implant 8 mm, regardless of manufacturer. For the screwretention type, minimal interocclusal distance were 1.5~4.5 mm for internal connection type, 3.65~4.5 mm for external connection type, 4.3~6.5 mm soft-tissue level implant. Conclusion: There were differences in each manufacturer, but implantation can be performed when the minimum interocclusal distance of 1.5 mm is secured. | - |
dc.description.statementOfResponsibility | open | - |
dc.language | Korean | - |
dc.publisher | 대한구강악안면임프란트학회 | - |
dc.relation.isPartOf | Journal of Korean Academy of Oral & Maxillofacial Implantology (대한구강악안면임프란트학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 임플란트 고정성 보철물 수복을 위한 최소 교합 고경에 대한 고찰 | - |
dc.title.alternative | Consideration of Minimal Interocclusal Distance for Implant-supported Prosthesis | - |
dc.type | Article | - |
dc.publisher.location | Korea | - |
dc.contributor.college | College of Dentistry | - |
dc.contributor.department | Dept. of Periodontology | - |
dc.contributor.googleauthor | 김승민 | - |
dc.contributor.googleauthor | 최순호 | - |
dc.contributor.googleauthor | 송영우 | - |
dc.contributor.googleauthor | 강주현 | - |
dc.contributor.googleauthor | 차재국 | - |
dc.contributor.googleauthor | 이중석 | - |
dc.contributor.googleauthor | 박영범 | - |
dc.contributor.googleauthor | 정의원 | - |
dc.contributor.localId | A04004 | - |
dc.contributor.localId | A05189 | - |
dc.contributor.localId | A05096 | - |
dc.contributor.localId | A01567 | - |
dc.contributor.localId | A05142 | - |
dc.contributor.localId | A03185 | - |
dc.contributor.localId | A03692 | - |
dc.contributor.localId | A05080 | - |
dc.relation.journalcode | J01489 | - |
dc.relation.journalsince | 1995~2002 | - |
dc.relation.journalafter | 2003~ Implantology | - |
dc.subject.keyword | Implant | - |
dc.subject.keyword | Implant prosthesis | - |
dc.subject.keyword | Interocclusal distance | - |
dc.subject.keyword | Minimal interocclusal distance | - |
dc.contributor.alternativeName | Kang, Joo Hyun | - |
dc.contributor.alternativeName | Cha, Jae Kook | - |
dc.contributor.alternativeName | Choe, Sun Ho | - |
dc.contributor.alternativeName | Kim, Seung Min | - |
dc.contributor.alternativeName | Park, Young Bum | - |
dc.contributor.alternativeName | Song, Young Woo | - |
dc.contributor.alternativeName | Lee, Jung Seok | - |
dc.contributor.alternativeName | Jung, Ui Won | - |
dc.contributor.affiliatedAuthor | Cha, Jae Kook | - |
dc.contributor.affiliatedAuthor | Choe, Sun Ho | - |
dc.contributor.affiliatedAuthor | Kim, Seung Min | - |
dc.contributor.affiliatedAuthor | Park, Young Bum | - |
dc.contributor.affiliatedAuthor | Song, Young Woo | - |
dc.contributor.affiliatedAuthor | Lee, Jung Seok | - |
dc.contributor.affiliatedAuthor | Jung, Ui Won | - |
dc.contributor.affiliatedAuthor | Kang, Joo Hyun | - |
dc.citation.title | Journal of Korean Academy of Oral & Maxillofacial Implantology (대한구강악안면임프란트학회지: Implantology) | - |
dc.citation.volume | 21 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 54 | - |
dc.citation.endPage | 64 | - |
dc.identifier.bibliographicCitation | Journal of Korean Academy of Oral & Maxillofacial Implantology (대한구강악안면임프란트학회지), Vol.21(1) : 54-64, 2017 | - |
dc.date.modified | 2017-11-01 | - |
dc.identifier.rimsid | 42188 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.