Cited 4 times in
A computerized red glass test for quantifying diplopia
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김경섭 | - |
dc.contributor.author | 남효석 | - |
dc.contributor.author | 유준상 | - |
dc.contributor.author | 유한수 | - |
dc.contributor.author | 장혁재 | - |
dc.contributor.author | 허지회 | - |
dc.contributor.author | 박은정 | - |
dc.date.accessioned | 2017-11-01T08:50:27Z | - |
dc.date.available | 2017-11-01T08:50:27Z | - |
dc.date.issued | 2017 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/153702 | - |
dc.description.abstract | BACKGROUND: Accurate evaluation of diplopia during bedside physical examination is challenging. We developed a new computerized red glass test (CRT) to detect, localize, and quantify diplopia and investigated whether the CRT is useful and feasible. METHODS: During the CRT, a white dot randomly appears on a monitor. Because a red glass is applied on the right eye, a patient can see one white dot and one red dot when diplopia is present. We defined the degree of diplopia as the direct distance of the two points with the largest deviation and compared the degree with the Hess score and Hess area ratio. RESULTS: We prospectively enrolled 14 patients with binocular diplopia. Test-retest reliability of the CRT was excellent (overall intraclass correlation coefficient = 0.948, 95% CI 0.939-0.956). The degree of diplopia in the CRT was well correlated with both the Hess score (r = 0.719, p = 0.005) and the Hess area ratio (r = -0.620, p = 0.018). CONCLUSIONS: The CRT can easily detect the presence of diplopia and provided the quantitative values of the degree of diplopia. The CRT was useful and feasible for improving routine bedside examination. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.publisher | BioMed Central | - |
dc.relation.isPartOf | BMC OPHTHALMOLOGY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Adult | - |
dc.subject.MESH | Aged | - |
dc.subject.MESH | Diagnosis, Computer-Assisted/methods* | - |
dc.subject.MESH | Diplopia/diagnosis* | - |
dc.subject.MESH | Diplopia/physiopathology | - |
dc.subject.MESH | Female | - |
dc.subject.MESH | Humans | - |
dc.subject.MESH | Male | - |
dc.subject.MESH | Middle Aged | - |
dc.subject.MESH | Optics and Photonics* | - |
dc.subject.MESH | Pilot Projects | - |
dc.subject.MESH | Prospective Studies | - |
dc.subject.MESH | Reproducibility of Results | - |
dc.subject.MESH | Visual Field Tests/methods | - |
dc.subject.MESH | Visual Fields/physiology* | - |
dc.subject.MESH | Young Adult | - |
dc.title | A computerized red glass test for quantifying diplopia | - |
dc.type | Article | - |
dc.publisher.location | England | - |
dc.contributor.college | College of Medicine | - |
dc.contributor.department | Dept. of Neurology | - |
dc.contributor.googleauthor | Han Soo Yoo | - |
dc.contributor.googleauthor | Eunjeong Park | - |
dc.contributor.googleauthor | Soolienah Rhiu | - |
dc.contributor.googleauthor | Hyuk-Jae Chang | - |
dc.contributor.googleauthor | Kyoungsub Kim | - |
dc.contributor.googleauthor | Joonsang Yoo | - |
dc.contributor.googleauthor | Ji Hoe Heo | - |
dc.contributor.googleauthor | Hyo Suk Nam | - |
dc.identifier.doi | 10.1186/s12886-017-0465-8 | - |
dc.contributor.localId | A01273 | - |
dc.contributor.localId | A02513 | - |
dc.contributor.localId | A03490 | - |
dc.contributor.localId | A04369 | - |
dc.contributor.localId | A01614 | - |
dc.contributor.localId | A05088 | - |
dc.contributor.localId | A05367 | - |
dc.relation.journalcode | J00370 | - |
dc.identifier.eissn | 1471-2415 | - |
dc.relation.journalsince | 2001~ | - |
dc.identifier.pmid | 28514951 | - |
dc.subject.keyword | Computer software | - |
dc.subject.keyword | Diplopia | - |
dc.subject.keyword | Neurologic examination | - |
dc.subject.keyword | Quantification | - |
dc.contributor.alternativeName | Kim, Kyoung Sub | - |
dc.contributor.alternativeName | Nam, Hyo Suk | - |
dc.contributor.alternativeName | Yoo, Joon Sang | - |
dc.contributor.alternativeName | Yoo, Han Su | - |
dc.contributor.alternativeName | Chang, Hyuck Jae | - |
dc.contributor.alternativeName | Heo, Ji Hoe | - |
dc.contributor.alternativeName | Bak, Eun-Jung | - |
dc.contributor.affiliatedAuthor | Nam, Hyo Suk | - |
dc.contributor.affiliatedAuthor | Yoo, Joon Sang | - |
dc.contributor.affiliatedAuthor | Chang, Hyuck Jae | - |
dc.contributor.affiliatedAuthor | Heo, Ji Hoe | - |
dc.contributor.affiliatedAuthor | Kim, Kyoung Sub | - |
dc.contributor.affiliatedAuthor | Yoo, Han Soo | - |
dc.citation.title | BMC Ophthalmology | - |
dc.citation.volume | 17 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 71 | - |
dc.identifier.bibliographicCitation | BMC OPHTHALMOLOGY, Vol.17(1) : 71, 2017 | - |
dc.date.modified | 2017-11-01 | - |
dc.identifier.rimsid | 42995 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.