Cited 4 times in

A computerized red glass test for quantifying diplopia

DC Field Value Language
dc.contributor.author김경섭-
dc.contributor.author남효석-
dc.contributor.author유준상-
dc.contributor.author유한수-
dc.contributor.author장혁재-
dc.contributor.author허지회-
dc.contributor.author박은정-
dc.date.accessioned2017-11-01T08:50:27Z-
dc.date.available2017-11-01T08:50:27Z-
dc.date.issued2017-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/153702-
dc.description.abstractBACKGROUND: Accurate evaluation of diplopia during bedside physical examination is challenging. We developed a new computerized red glass test (CRT) to detect, localize, and quantify diplopia and investigated whether the CRT is useful and feasible. METHODS: During the CRT, a white dot randomly appears on a monitor. Because a red glass is applied on the right eye, a patient can see one white dot and one red dot when diplopia is present. We defined the degree of diplopia as the direct distance of the two points with the largest deviation and compared the degree with the Hess score and Hess area ratio. RESULTS: We prospectively enrolled 14 patients with binocular diplopia. Test-retest reliability of the CRT was excellent (overall intraclass correlation coefficient = 0.948, 95% CI 0.939-0.956). The degree of diplopia in the CRT was well correlated with both the Hess score (r = 0.719, p = 0.005) and the Hess area ratio (r = -0.620, p = 0.018). CONCLUSIONS: The CRT can easily detect the presence of diplopia and provided the quantitative values of the degree of diplopia. The CRT was useful and feasible for improving routine bedside examination.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.publisherBioMed Central-
dc.relation.isPartOfBMC OPHTHALMOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAged-
dc.subject.MESHDiagnosis, Computer-Assisted/methods*-
dc.subject.MESHDiplopia/diagnosis*-
dc.subject.MESHDiplopia/physiopathology-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMale-
dc.subject.MESHMiddle Aged-
dc.subject.MESHOptics and Photonics*-
dc.subject.MESHPilot Projects-
dc.subject.MESHProspective Studies-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHVisual Field Tests/methods-
dc.subject.MESHVisual Fields/physiology*-
dc.subject.MESHYoung Adult-
dc.titleA computerized red glass test for quantifying diplopia-
dc.typeArticle-
dc.publisher.locationEngland-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Neurology-
dc.contributor.googleauthorHan Soo Yoo-
dc.contributor.googleauthorEunjeong Park-
dc.contributor.googleauthorSoolienah Rhiu-
dc.contributor.googleauthorHyuk-Jae Chang-
dc.contributor.googleauthorKyoungsub Kim-
dc.contributor.googleauthorJoonsang Yoo-
dc.contributor.googleauthorJi Hoe Heo-
dc.contributor.googleauthorHyo Suk Nam-
dc.identifier.doi10.1186/s12886-017-0465-8-
dc.contributor.localIdA01273-
dc.contributor.localIdA02513-
dc.contributor.localIdA03490-
dc.contributor.localIdA04369-
dc.contributor.localIdA01614-
dc.contributor.localIdA05088-
dc.contributor.localIdA05367-
dc.relation.journalcodeJ00370-
dc.identifier.eissn1471-2415-
dc.relation.journalsince2001~-
dc.identifier.pmid28514951-
dc.subject.keywordComputer software-
dc.subject.keywordDiplopia-
dc.subject.keywordNeurologic examination-
dc.subject.keywordQuantification-
dc.contributor.alternativeNameKim, Kyoung Sub-
dc.contributor.alternativeNameNam, Hyo Suk-
dc.contributor.alternativeNameYoo, Joon Sang-
dc.contributor.alternativeNameYoo, Han Su-
dc.contributor.alternativeNameChang, Hyuck Jae-
dc.contributor.alternativeNameHeo, Ji Hoe-
dc.contributor.alternativeNameBak, Eun-Jung-
dc.contributor.affiliatedAuthorNam, Hyo Suk-
dc.contributor.affiliatedAuthorYoo, Joon Sang-
dc.contributor.affiliatedAuthorChang, Hyuck Jae-
dc.contributor.affiliatedAuthorHeo, Ji Hoe-
dc.contributor.affiliatedAuthorKim, Kyoung Sub-
dc.contributor.affiliatedAuthorYoo, Han Soo-
dc.citation.titleBMC Ophthalmology-
dc.citation.volume17-
dc.citation.number1-
dc.citation.startPage71-
dc.identifier.bibliographicCitationBMC OPHTHALMOLOGY, Vol.17(1) : 71, 2017-
dc.date.modified2017-11-01-
dc.identifier.rimsid42995-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Research Institute (부설연구소) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Neurology (신경과학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Plastic and Reconstructive Surgery (성형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.