645 730

Cited 0 times in

깊이 카메라를 이용한 호흡률 측정에 미치는 영향 요인 분석

DC Field Value Language
dc.contributor.author김정민-
dc.contributor.author신증수-
dc.contributor.author유선국-
dc.contributor.author장원석-
dc.date.accessioned2017-10-26T07:39:03Z-
dc.date.available2017-10-26T07:39:03Z-
dc.date.issued2016-
dc.identifier.issn1226-8593-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/152326-
dc.description.abstractThe purpose of this research was to analyze several factors that can affect the respiration rate measurement using the Creative Senz3D depth camera. Depth error and noise of the depth camera were considered as affecting factors. Ambient light was also considered. The result of this study showed that the depth error was increased with an increase of the distance between subject and depth camera. The result also showed depth asymmetry in the depth image. The depth values measured in right region of the depth image was higher than real distance and depth values measured in left of the depth image was lower than real distance. The difference error of the depth was influenced by the orientation of the depth camera. The noise created by the depth camera was increased as the distance between subject and depth camera was increased and it decreased as the window size was increased which was used to calculate noise level. Ambient light seems to have no influence on the depth value. In real environment, we measured respiration rate. Participants were asked to breathe 20 times. We could find that the respiration rate which was measured from depth camera shows excellent agreement with that of participants.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean-
dc.publisher한국감성과학회-
dc.relation.isPartOfKorean Journal of the Science of Emotion & Sensibility (감성과학)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title깊이 카메라를 이용한 호흡률 측정에 미치는 영향 요인 분석-
dc.title.alternativeAffecting Factor Analysis for Respiration Rate Measurement Using Depth Camera-
dc.typeArticle-
dc.publisher.locationKorea-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Anesthesiology and Pain Medicine-
dc.contributor.googleauthor오경택-
dc.contributor.googleauthor신증수-
dc.contributor.googleauthor김정민-
dc.contributor.googleauthor장원석-
dc.contributor.googleauthor유선국-
dc.identifier.doi10.14695/KJSOS.2016.19.3.81-
dc.contributor.localIdA02159-
dc.contributor.localIdA02471-
dc.contributor.localIdA00884-
dc.relation.journalcodeJ02124-
dc.subject.keywordAffect Factor Analysis-
dc.subject.keywordDepth Camera-
dc.subject.keywordDepth Sensor-
dc.subject.keywordNon-contact-
dc.subject.keywordRespiration-
dc.subject.keywordRespiration Rate-
dc.contributor.alternativeNameKim, Jeongmin-
dc.contributor.alternativeNameShin, Cheung Soo-
dc.contributor.alternativeNameYoo, Sun Kook-
dc.contributor.affiliatedAuthorShin, Cheung Soo-
dc.contributor.affiliatedAuthorYoo, Sun Kook-
dc.contributor.affiliatedAuthorKim, Jeongmin-
dc.citation.volume19-
dc.citation.number3-
dc.citation.startPage81-
dc.citation.endPage88-
dc.identifier.bibliographicCitationKorean Journal of the Science of Emotion & Sensibility, Vol.19(3) : 81-88, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid48061-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Anesthesiology and Pain Medicine (마취통증의학교실) > 1. Journal Papers
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.