Cited 5 times in
Effects of thread size in the implant neck area on peri-implant hard and soft tissues: an animal study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 문익상 | - |
dc.contributor.author | 박광호 | - |
dc.contributor.author | 이동원 | - |
dc.contributor.author | 허종기 | - |
dc.date.accessioned | 2017-10-26T07:36:06Z | - |
dc.date.available | 2017-10-26T07:36:06Z | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 0905-7161 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/152255 | - |
dc.description.abstract | Objectives : The aim of this animal study was to examine the effects of thread size in the implant neck area on peri-implant tissues in terms of BIC and hard- and soft-tissue dimensions. Materials and methods : Six Beagle dogs received experimental implants in the mandible 3 month after the removal of premolars and first molars (P2, P3, P4, and M1). Two different types of implants were installed in each animal: Anyone microthread® as Group 1 and Anyone® as Group 2. Resonance frequency test, intraoral radiography, micro-CT, and histomorphometry were used to evaluate peri-implant tissue after implantation periods of 4 and 8 weeks. Results : No remarkable complication was observed during the healing period in either group. Resonance frequency testing revealed no significant difference between groups. In radiographic evaluation, Group 2 showed more bone loss than Group 1. However, this difference was not statistically significant. In the micro-CT analysis, BIC and BIV values and soft-tissue height were not significant in both groups. Histological analysis revealed no significant difference in BIC ratio, bone density, or bone loss between groups. However, soft-tissue height was significantly greater in Group 2 than in Group 1 (P = 0.0004). Conclusion : No difference in peri-implant hard or soft tissues was observed according to thread size in the implant neck area. | - |
dc.description.statementOfResponsibility | restriction | - |
dc.language | English | - |
dc.publisher | John Wiley and Sons, Inc. | - |
dc.relation.isPartOf | CLINICAL ORAL IMPLANTS RESEARCH | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Alveolar Process/diagnostic imaging | - |
dc.subject.MESH | Alveolar Process/pathology | - |
dc.subject.MESH | Alveolar Process/surgery* | - |
dc.subject.MESH | Animals | - |
dc.subject.MESH | Cone-Beam Computed Tomography | - |
dc.subject.MESH | Dental Implantation, Endosseous/adverse effects* | - |
dc.subject.MESH | Dental Implantation, Endosseous/instrumentation | - |
dc.subject.MESH | Dental Implantation, Endosseous/methods | - |
dc.subject.MESH | Dental Implants/adverse effects* | - |
dc.subject.MESH | Dogs | - |
dc.subject.MESH | Gingiva/diagnostic imaging | - |
dc.subject.MESH | Gingiva/pathology | - |
dc.subject.MESH | Gingiva/surgery* | - |
dc.subject.MESH | X-Ray Microtomography | - |
dc.title | Effects of thread size in the implant neck area on peri-implant hard and soft tissues: an animal study | - |
dc.type | Article | - |
dc.publisher.location | Denmark | - |
dc.contributor.college | College of Dentistry | - |
dc.contributor.department | Dept. of Periodontology | - |
dc.contributor.googleauthor | Jay-Yong Choi | - |
dc.contributor.googleauthor | Ik-Sang Moon | - |
dc.contributor.googleauthor | Jeong-Ho Yun | - |
dc.contributor.googleauthor | Kwang-Ho Park | - |
dc.contributor.googleauthor | Jong-Ki Huh | - |
dc.contributor.googleauthor | Dong-Won Lee | - |
dc.identifier.doi | 10.1111/clr.12720 | - |
dc.contributor.localId | A01435 | - |
dc.contributor.localId | A02728 | - |
dc.contributor.localId | A04365 | - |
dc.contributor.localId | A01373 | - |
dc.relation.journalcode | J00600 | - |
dc.identifier.eissn | 1600-0501 | - |
dc.identifier.pmid | 26498561 | - |
dc.identifier.url | http://onlinelibrary.wiley.com/doi/10.1111/clr.12720/abstract | - |
dc.subject.keyword | CT imaging | - |
dc.subject.keyword | animal experiments | - |
dc.subject.keyword | bone implant interactions | - |
dc.subject.keyword | morphometric analysis | - |
dc.subject.keyword | soft tissue-implant interactions | - |
dc.contributor.alternativeName | Moon, Ik Sang | - |
dc.contributor.alternativeName | Park, Kwang Ho | - |
dc.contributor.alternativeName | Lee, Dong Won | - |
dc.contributor.alternativeName | Huh, Jong Ki | - |
dc.contributor.affiliatedAuthor | Park, Kwang Ho | - |
dc.contributor.affiliatedAuthor | Lee, Dong Won | - |
dc.contributor.affiliatedAuthor | Huh, Jong Ki | - |
dc.contributor.affiliatedAuthor | Moon, Ik Sang | - |
dc.citation.volume | 27 | - |
dc.citation.number | 9 | - |
dc.citation.startPage | 1187 | - |
dc.citation.endPage | 1192 | - |
dc.identifier.bibliographicCitation | CLINICAL ORAL IMPLANTS RESEARCH, Vol.27(9) : 1187-1192, 2016 | - |
dc.date.modified | 2017-10-24 | - |
dc.identifier.rimsid | 47992 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.