0 494

Cited 9 times in

Preclinical assessment of a modified Occlutech left atrial appendage closure device in a canine model

DC Field Value Language
dc.contributor.author김중선-
dc.contributor.author심지영-
dc.contributor.author장양수-
dc.contributor.author최동훈-
dc.contributor.author홍그루-
dc.date.accessioned2017-10-26T07:13:54Z-
dc.date.available2017-10-26T07:13:54Z-
dc.date.issued2016-
dc.identifier.issn0167-5273-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151770-
dc.description.abstractBACKGROUND: LAA occlusion has a similar stroke prevention efficacy compared to anticoagulation treatment for non-valvular atrial fibrillation. OBJECTIVE: The objective of this study was to assess the feasibility and safety of a modified Occlutech® left atrial appendage (LAA) closure device in a canine model. METHODS: The device was implanted in 10 dogs (33±1kg) using fluoroscopy and transesophageal echocardiography (TEE) guidance. The modified Occlutech® LAA occlusion device was compared with the current version, the Watchman device, and the Amplazter cardiac plug (ACP). LAA occlusion and anchoring to the LAA were evaluated. All dogs were assessed using angiography, TEE, and a gross anatomy examination. RESULTS: The 10 LAA occlusion devices were to be implanted into 10 dogs (5 modified Occlutech devices, 3 current version of Occlutech devices, 1 Watchman, and 1 ACP). LAA implantation was not performed in one dog due to transeptal puncture failure. The three current version of Occlutech devices were embolized immediately after implantation, so three modified devices of the same size were implanted securely without embolization. The mean implant size was 20.1±2.0mm. The devices chosen were a mean of 23.3±10.6% larger than the measured landing zone diameters. Post-implant angiography and TEE revealed well-positioned devices without pericardial effusion or impingement on surrounding structures. CONCLUSIONS: The results of this acute animal study suggested that a modified Occlutech® LAA occlusion device was feasible and had greater anchoring performance in canines. Additional large clinical studies are needed to evaluate safety and efficacy.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherElsevier-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF CARDIOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHAtrial Appendage/surgery*-
dc.subject.MESHAtrial Fibrillation/surgery*-
dc.subject.MESHDisease Models, Animal-
dc.subject.MESHDogs-
dc.subject.MESHProsthesis Implantation*/instrumentation-
dc.subject.MESHProsthesis Implantation*/methods-
dc.subject.MESHSeptal Occluder Device*-
dc.subject.MESHStroke/prevention & control*-
dc.titlePreclinical assessment of a modified Occlutech left atrial appendage closure device in a canine model-
dc.typeArticle-
dc.publisher.locationNetherlands-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Internal Medicine-
dc.contributor.googleauthorJung-Sun Kim-
dc.contributor.googleauthorSeul-Gee Lee-
dc.contributor.googleauthorSung-Kyung Bong-
dc.contributor.googleauthorSe-Il Park-
dc.contributor.googleauthorSung-Yu Hong-
dc.contributor.googleauthorSanghoon Shin-
dc.contributor.googleauthorChi Young Shim-
dc.contributor.googleauthorGeu-Ru Hong-
dc.contributor.googleauthorDonghoon Choi-
dc.contributor.googleauthorYangsoo Jang-
dc.contributor.googleauthorJai-Wun Park-
dc.identifier.doi10.1016/j.ijcard.2016.07.048-
dc.contributor.localIdA02213-
dc.contributor.localIdA03448-
dc.contributor.localIdA04053-
dc.contributor.localIdA04386-
dc.contributor.localIdA00961-
dc.relation.journalcodeJ01093-
dc.identifier.eissn1874-1754-
dc.identifier.pmid27404716-
dc.identifier.urlhttp://www.sciencedirect.com/science/article/pii/S0167527316314103-
dc.subject.keywordCanine model-
dc.subject.keywordDevice study-
dc.subject.keywordLeft atrial appendage-
dc.contributor.alternativeNameKim, Jung Sun-
dc.contributor.alternativeNameShim, Chi Young-
dc.contributor.alternativeNameJang, Yang Soo-
dc.contributor.alternativeNameChoi, Dong Hoon-
dc.contributor.alternativeNameHong, Geu Ru-
dc.contributor.affiliatedAuthorShim, Chi Young-
dc.contributor.affiliatedAuthorJang, Yang Soo-
dc.contributor.affiliatedAuthorChoi, Dong Hoon-
dc.contributor.affiliatedAuthorHong, Geu Ru-
dc.contributor.affiliatedAuthorKim, Jung Sun-
dc.citation.volume221-
dc.citation.startPage413-
dc.citation.endPage418-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF CARDIOLOGY, Vol.221 : 413-418, 2016-
dc.date.modified2017-10-24-
dc.identifier.rimsid45781-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.