0 459

Cited 19 times in

Optimal boundary detection method and window settings for coronary atherosclerotic plaque volume analysis in coronary computed tomography angiography: comparison with intravascular ultrasound

Authors
 Ran Heo  ;  Hyung-Bok Park  ;  Byoung Kwon Lee  ;  Sanghoon Shin  ;  Reza Arsanjani  ;  James K. Min  ;  Hyuk-Jae Chang 
Citation
 EUROPEAN RADIOLOGY, Vol.26(9) : 3190-3198, 2016 
Journal Title
EUROPEAN RADIOLOGY
ISSN
 0938-7994 
Issue Date
2016
MeSH
Aged ; Computed Tomography Angiography/methods* ; Coronary Angiography/methods* ; Coronary Artery Disease/diagnosis* ; Coronary Vessels/diagnostic imaging* ; Female ; Humans ; Male ; Middle Aged ; Plaque, Atherosclerotic/diagnosis* ; Ultrasonography, Interventional/methods*
Keywords
Boundary detection ; Coronary CT angiography ; Intravascular ultrasound ; Quantitative plaque volume analysis ; Window settings
Abstract
OBJECTIVE: To evaluate optimal methodology for quantitative plaque volume analysis by coronary CT angiography (QCT).

METHODS: Fifty-one coronary artery segments were evaluated and contour measurements based on two different methods [(1) no gap, or (2) fixed 0.3-mm gap between inner and outer boundary] were compared with intravascular ultrasound (IVUS). In addition, three different window width (WW) and level (WL) settings [fixed (740/220) Hounsfield unit (HU), adjusted (155 % and 65 % of mean luminal intensity of the segment, and aorta adjusted (155 % and 65 % of mean luminal intensity of central aorta)] were used for semiautomated plaque volume analysis.

RESULTS: For boundary detection, the no gap method led to underestimation compared with IVUS (105.4?±?82.3 vs. 136.1?±?72.8 mm(3), p?
CONCLUSION: For plaque volumetric assessment, optimal results were obtained with fixed 0.3-mm gap with fixed HU setting (740/220).

KEY POINTS: ? Quantitative plaque volume analysis by coronary CT angiography has recently emerged. ? Different boundary detection methods and window width and level settings were evaluated. ? Fixed 0.3-mm gap with fixed HU setting (740/220) afforded optimal results
Full Text
http://link.springer.com/article/10.1007%2Fs00330-015-4121-5
DOI
10.1007/s00330-015-4121-5
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Byoung Kwon(이병권) ORCID logo https://orcid.org/0000-0001-9259-2776
Chang, Hyuk-Jae(장혁재) ORCID logo https://orcid.org/0000-0002-6139-7545
Heo, Ran(허란)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/151712