0 547

Cited 21 times in

Analysis of 30 Breast Implant Rupture Cases

DC Field Value Language
dc.contributor.author노태석-
dc.contributor.author최종우-
dc.contributor.author탁관철-
dc.contributor.author정희선-
dc.date.accessioned2017-10-26T06:48:34Z-
dc.date.available2017-10-26T06:48:34Z-
dc.date.issued2005-
dc.identifier.issn0364-216X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151332-
dc.description.abstractBreast implants used for augmentation mammoplasty or breast reconstruction could rupture from various causes such as trauma or spontaneous failure. The objectives of this study were to investigate the relationships between the causes of implant rupture and the degree of capsular contracture, and then to evaluate the relative efficacies of specific signs on magnetic resonance imaging (MRI) known to be beneficial for diagnosing the rupture. A retrospective review identified patients with prosthetic implant rupture or impending rupture treated by the senior author. The 30 cases of implant rupture available for review were classified into two groups: intracapsular and extracapsular ruptures. The 30 cases of breast implant ruptures were analyzed with respect to the clinical symptoms and signs, the causes of rupture, the degree of capsular contracture, and therapeutic plans. Among the 30 cases, 14 patients who had undergone MRI during the diagnostic period were analyzed with respect to the relationships between MRI readings and operative findings. Spontaneous rupture of membranes was most common (80%), followed by failure because of trauma (7%) and valve or implant base (4%). The symptoms during implant rupture were contour deformity, palpated masslike lesions, pain, and focal inflammation. According to the analysis of specific MRI signs, the sensitivity and specificity of the linguine sign were 87% and 100%, respectively, for intracapsular rupture. For extracapsular rupture, the sensitivity and specificity of the linguine sign were, respectively, 67% and 75%. The sensitivity and specificity of the rat-tail sign and tear drop sign were 14% and 50%, respectively. Breast implant rupture was correlated with the degree of capsular contracture in our study. Among the various specific MRI signs used in diagnosing the rupture, the linguine sign was reliable and had a high sensitivity and specificity, especially in cases of intracapsular rupture. On the other hand, the rat-tail and tear drop signs were nonspecific signs for diagnosing the rupture of breast implant.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherSpringer-Verlag-
dc.relation.isPartOfAESTHETIC PLASTIC SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHBreast Implants*-
dc.subject.MESHFemale-
dc.subject.MESHHumans-
dc.subject.MESHMiddle Aged-
dc.subject.MESHPostoperative Complications-
dc.subject.MESHReoperation-
dc.subject.MESHRetrospective Studies-
dc.titleAnalysis of 30 Breast Implant Rupture Cases-
dc.typeArticle-
dc.publisher.locationUnited States-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Plastic and Reconstructive Surgery (성형외과학교실)-
dc.contributor.departmentDept. of Plastic and Reconstructive Surgery (성형외과학교실)-
dc.contributor.departmentDept. of Plastic and Reconstructive Surgery (성형외과학교실)-
dc.contributor.googleauthorKwan Chul Tark-
dc.contributor.googleauthorHii Sun Jeong-
dc.contributor.googleauthorTae Suk Roh-
dc.contributor.googleauthorJong Woo Choi-
dc.identifier.doi10.1007/s00266-004-0146-x-
dc.contributor.localIdA01297-
dc.contributor.localIdA04184-
dc.contributor.localIdA04236-
dc.relation.journalcodeJ00050-
dc.identifier.eissn1432-5241-
dc.identifier.pmid16328645-
dc.identifier.urlhttp://link.springer.com/article/10.1007%2Fs00266-004-0146-x-
dc.subject.keywordMRI-
dc.subject.keywordRadiologic sign-
dc.subject.keywordRupture of breast implant-
dc.contributor.alternativeNameRoh, Tai Suk-
dc.contributor.alternativeNameRoh, Tai Suk-
dc.contributor.alternativeNameChoi, Jong Woo-
dc.contributor.alternativeNameTark, Kwan Chul-
dc.contributor.affiliatedAuthor노태석-
dc.citation.volume29-
dc.citation.number6-
dc.citation.startPage460-
dc.citation.endPage469-
dc.identifier.bibliographicCitationAESTHETIC PLASTIC SURGERY, Vol.29(6) : 460-469, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid44049-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Plastic and Reconstructive Surgery (성형외과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.