0 363

Cited 0 times in

Improvement in the GC-MS method for determining urinary toluene-diamine and its application to the biological monitoring of workers exposed to toluene-diisocyanate

Authors
 Tadashi Sakai  ;  Yoko Morita  ;  Jaehoon Roh  ;  Hyoungryoul Kim  ;  Yangho Kim 
Citation
 INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH, Vol.78(6) : 459-466, 2005 
Journal Title
INTERNATIONAL ARCHIVES OF OCCUPATIONAL AND ENVIRONMENTAL HEALTH
ISSN
 0340-0131 
Issue Date
2005
MeSH
Air Pollutants, Occupational/toxicity* ; Biomarkers/urine ; Creatinine/urine ; Gas Chromatography-Mass Spectrometry ; Humans ; Male ; Occupational Exposure* ; Phenylenediamines/urine* ; Specific Gravity ; Toluene 2,4-Diisocyanate/toxicity*
Keywords
Biological monitoring ; Personal exposure ; Toluene-diamine ; Toluene-diisocyanate ; Urine
Abstract
OBJECTIVES: To develop a simple and sensitive GC-MS method for determining toluene-diamine (TDA) in urine and to apply the method for biological monitoring of workers exposed to toluene-diisocyanate (TDI).
METHODS: After acid hydrolysis of 0.1 ml of urine, diluted tenfold with water, for 1.5 h, the free TDA formed was extracted with dichloromethane, and the heptafluorobutyric anhydride derivative was determined by GC-MS. We applied the method to the biological monitoring of 18 workers who were using an 80:20 mixture of 2,4-TDI and 2,6-TDI.
RESULTS: 2,6-TDA and 2,4-TDA were simply determined in 7 min by GC-MS. TDA levels in post-shift urine were well correlated with personal exposure levels of TDI. The correlation was improved by correction with creatinine or specific gravity in the 2,6-isomer, but not in the 2,4-isomer because of low exposure levels. From the correlation equation, the 2,6-TDA level (corrected with creatinine), corresponding to the TDI level of 5 ppb, was calculated to be 31.6 mug/g Cre. TDAs in pre-shift urine also correlated significantly with the personal exposure levels of TDIs, although the slope of the correlations for pre-shift samples was 60%-70% of those for post-shift samples. The correlation between 2,4-TDA and 2,6-TDA levels was significant, although the levels of the 2,4-isomer were less than one-tenth of the 2,6-isomers in both air (personal exposure) and urine.
CONCLUSION: The present method is simple and practicable and can be useful for biological monitoring of TDI workers.
Full Text
http://link.springer.com/article/10.1007%2Fs00420-004-0571-9
DOI
OAK-2005-05599
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Preventive Medicine (예방의학교실) > 1. Journal Papers
Yonsei Authors
Roh, Jae Hoon(노재훈)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/151219
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links