399 436

Cited 0 times in

근위 대퇴정을 이용한 대퇴골 전자간 역사상 불안정 분쇄 골절의 치료

Other Titles
 The Treatment of Unstable Reverse Oblique Intertrochanteric Fractures with Proximal Femoral Nail (PFN) 
Authors
 유제현  ;  양규현  ;  박시영  ;  원정훈  ;  윤한국 
Citation
 Journal of the Korean Orthopaedic Association (대한정형외과학회지), Vol.40(6) : 733-740, 2005 
Journal Title
Journal of the Korean Orthopaedic Association(대한정형외과학회지)
ISSN
 1226-2102 
Issue Date
2005
MeSH
Femur ; Intertrochanteric fracture ; Proximal femoral nail
Keywords
Femur ; Intertrochanteric fracture ; Proximal femoral nail
Abstract
Purpose: To investigate the results of treatment of unstable reverse oblique intertrochanteric fractures with proximal femoral nail (PFN).
Materials and Methods: We reviewed the results of 16 cases of AO 31-A3.3 intertrochanteric fracture treated with PFN from September 2000 to February 2004 which could be followed up for more than six months and untill bone union. The mean age was 60.2 years old. We investigated the union time and amount of sliding of two screws (neck screw and anti-rotational hip pin) and complications such as fixation failure and nonunion. Functional results were evaluated by the Parker and Palmer mobility score and Jensen social-function score.
Results: All fractures were united and the mean union time were 6.9 months. The amount of sliding of the neck screws and anti-rotational hip pin was 4.8 ㎜ and 3.8 ㎜ on average in 14 cases, respectively. Fixation failure and excessive migration of the screws occurred in two cases; One case showed so-called Z-effect of two screws (reciprocal movement of two screws) and nonunion. The other case showed proximal migration and cutout of the neck screw. There was one femoral shaft fracture at the nail tip caused by a slip. Eight cases (50%) and eleven cases(68%) were fully recovered according to parker and Palmer mobility score and Jensen social-function score, respectively.
Conclusion: We consider that PFN is a suitable implant for treatment of unstable reverse oblique intertrochanteric fractures. However, the revision of implant design is recommended to prevent the excessive migration of the femoral neck screw and anti-rotational hip pin.
Files in This Item:
T200501002.pdf Download
DOI
OAK-2005-05093
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
Yonsei Authors
Park, Si Young(박시영)
Yang, Kyu Hyun(양규현) ORCID logo https://orcid.org/0000-0001-7183-588X
Won, Jung Hoon(원정훈)
Yoo, Je Hyun(유제현)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/151137
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links