332 514

Cited 0 times in

경직형 뇌성마비에서 족저압 측정을 이용한 첨족 변형 교정 수술의 평가

DC Field Value Language
dc.contributor.author나동욱-
dc.contributor.author박은숙-
dc.date.accessioned2017-10-26T06:33:51Z-
dc.date.available2017-10-26T06:33:51Z-
dc.date.issued2005-
dc.identifier.issn1225-584X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/151000-
dc.description.abstractObjective: The aim of this study was to identify the changes of pressure distribution on the foot after orthopaedic surgery for equinus deformity in spastic cerebral palsy using F-scan system. Methods: Twenty-one children with spastic cerebral palsy were participated in this study. They had equinus deformity on foot and received soft tissue surgery. Pressure distribution on foot was measured before and after operation using F-scan system (Tekscan Inc., USA). Paired t-test was used in comparison of preoperative and postoperative measurements for statistical analysis. Results: Total contact area, contact length, midfoot and hindfoot contact width were significantly increased after operation. Relative impulses of medial and lateral forefoot were significantly decreased and relative impulse of hindfoot significantly increased after operation (p<0.05). Anteroposterior distance of center of pressure (COP) and velocity of COP were significantly increased and mediolateral distance and slope of COP were significantly decreased after operation (p<0.05). Conclusion: This study revealed that patterns of foot pressure distribution during walking were significantly improved after operation. Therefore, these findings suggested that F- scan system might be useful for surgical outcome measurement for foot deformities in the children with spastic cerebral palsy.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한재활의학회-
dc.relation.isPartOfJournal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHCerebral palsy-
dc.subject.MESHEquinus deformity-
dc.subject.MESHFoot pressure distribution-
dc.subject.MESHF-scan system-
dc.title경직형 뇌성마비에서 족저압 측정을 이용한 첨족 변형 교정 수술의 평가-
dc.title.alternativeThe Changes of Foot Pressure Distribution in Spastic Cerebral Palsy with Equinus Deformity following Corrective Surgery-
dc.typeArticle-
dc.publisher.locationKorea-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Rehabilitation Medicine (재활의학교실)-
dc.contributor.departmentDept. of Rehabilitation Medicine (재활의학교실)-
dc.contributor.googleauthor박은숙-
dc.contributor.googleauthor나동욱-
dc.contributor.googleauthor최종은-
dc.contributor.googleauthor박찬우-
dc.contributor.googleauthor정호익-
dc.identifier.doiOAK-2005-04427-
dc.contributor.localIdA01230-
dc.contributor.localIdA01611-
dc.relation.journalcodeJ01803-
dc.relation.journalsince1977~2011-
dc.relation.journalafter2011~ Annals of Rehabilitation Medicine-
dc.subject.keywordCerebral palsy-
dc.subject.keywordEquinus deformity-
dc.subject.keywordFoot pressure distribution-
dc.subject.keywordF-scan system-
dc.contributor.alternativeNameRha, Dong Wook-
dc.contributor.alternativeNamePark, Eun Sook-
dc.citation.volume29-
dc.citation.number5-
dc.citation.startPage507-
dc.citation.endPage512-
dc.identifier.bibliographicCitationJournal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지), Vol.29(5) : 507-512, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid42880-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Rehabilitation Medicine (재활의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.