547 501

Cited 0 times in

부등시 교정렌즈가 부등상시 및 양안시 기능에 미치는 영향

DC Field Value Language
dc.contributor.author이종복-
dc.date.accessioned2017-09-30T06:32:19Z-
dc.date.available2017-09-30T06:32:19Z-
dc.date.issued2005-
dc.identifier.issn0378-6471-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/150013-
dc.description.abstractPurpose: To study the effect of the corrective lens for anisometropia on aniseikonia and binocular function. Methods: The study subjects were 30 patients without strabismus and amblyopia, who had anisometropia of more than 1.00D between the spherical equivalent of each correction lens. The amount of aniseikonia was measured by Awaya´s New Aniseikonia Test. The degree of stereopsis and fusion were determined with Titmus Stereo Test and fusion card of major amblyoscope, respectively. Results: The amount of aniseikonia increased significantly with increasing level of anisometropia (p=0.000). There was a statistically significant correlation between the amount of anisometropia and fusion (p=0.046). With increased aniseikonia, the stereopsis declined consequently, but the decline was not statistically significant. Aniseikonia was induced when there was more than 2.00D of anisometropia. With anisometropia increased by 1.00D, the odds ratio of induced aniseikonia was 7.197 (p=0.047). Conclusions: Anisometropia is an important factor for aniseikonia and can disturb binocular function.-
dc.description.statementOfResponsibilityopen-
dc.languageKorean-
dc.publisher대한안과학회-
dc.relation.isPartOfJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAniseikonia-
dc.subject.MESHAnisometropia-
dc.subject.MESHFusion-
dc.subject.MESHStereopsis-
dc.title부등시 교정렌즈가 부등상시 및 양안시 기능에 미치는 영향-
dc.title.alternativeEffect of Correction Lens for Anisometropia on Aniseikonia and Binocular Function-
dc.typeArticle-
dc.publisher.locationKorea-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학교실)-
dc.contributor.googleauthor이마빈-
dc.contributor.googleauthor양홍석-
dc.contributor.googleauthor유호민-
dc.contributor.googleauthor이종복-
dc.contributor.googleauthor장윤희-
dc.identifier.doiOAK-2005-03659-
dc.contributor.localIdA03140-
dc.relation.journalcodeJ01838-
dc.identifier.eissn2092-9374-
dc.subject.keywordAniseikonia-
dc.subject.keywordAnisometropia-
dc.subject.keywordFusion-
dc.subject.keywordStereopsis-
dc.contributor.alternativeNameLee, Jong Bok-
dc.citation.volume46-
dc.citation.number7-
dc.citation.startPage1183-
dc.citation.endPage1188-
dc.identifier.bibliographicCitationJOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.46(7) : 1183-1188, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid42695-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.