Cited 55 times in

Corrosion resistance of titanium–silver alloys in an artificial saliva containing fluoride ions

DC Field Value Language
dc.contributor.author김경남-
dc.contributor.author심형민-
dc.contributor.author황충주-
dc.date.accessioned2017-05-04T07:38:20Z-
dc.date.available2017-05-04T07:38:20Z-
dc.date.issued2005-
dc.identifier.issn1552-4973-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/147572-
dc.description.abstractDental gels and rinses for caries prophylactic contain fluoride at concentrations ranging from 0.1 to 1%. In addition, many types of fluoride-releasing materials have been used in dental applications. The purpose of the study was to investigate the addition effect of fluoride into artificial saliva on the corrosion resistance of pure titanium and titanium–silver alloys. Titanium and titanium–silver alloys were arc melted, homogenized at 950°C for 72 h, hot rolled, and solution heat treated and quenched. In order to investigate the effect of the fluoride ions on the corrosion resistance, potentiodynamic polarization testing, potentiostatic testing, and open-circuit potential measurements were performed in plain artificial saliva and 0.1 and 1% NaF-added artificial saliva. The passive current densities of titanium and titanium–silver alloys increased with increasing fluoride-ion concentration. Ti2.0Ag and Ti3.0Ag exhibited a low current density relatively and showed a stable behavior compared to titanium. The open-circuit potential of titanium decreased and current density at 250 mV (SCE) potentiostatic testing reacted sensitively with increasing fluoride concentration. On the other hand, the open-circuit potential of titanium–silver alloys with a high silver content (3.0–4.0 at %) reacted less sensitively to the fluoride-ion concentration. Among titanium–silver alloys, Ti3.0Ag alloy had a higher resistance against the attack of fluoride ions and showed a more stable open-circuit potential and current density than titanium in the fluoride-containing solution. It is concluded that they are electrochemically stable and maintained good corrosion resistance in fluoride-containing artificial saliva.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherJohn Wiley & Sons-
dc.relation.isPartOfJOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHBiocompatible Materials-
dc.subject.MESHDental Alloys*-
dc.subject.MESHDental Materials-
dc.subject.MESHMaterials Testing-
dc.subject.MESHPotentiometry-
dc.subject.MESHSaliva, Artificial*-
dc.subject.MESHSilver*-
dc.subject.MESHTitanium*-
dc.titleCorrosion resistance of titanium–silver alloys in an artificial saliva containing fluoride ions-
dc.typeArticle-
dc.publisher.locationUnited States-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실)-
dc.contributor.departmentDept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실)-
dc.contributor.departmentDept. of Orthodontics (교정과학교실)-
dc.contributor.googleauthorHyung-Min Shim-
dc.contributor.googleauthorKeun-Taek Oh-
dc.contributor.googleauthorJae-Young Woo-
dc.contributor.googleauthorChung-Ju Hwang-
dc.contributor.googleauthorKyoung-Nam Kim-
dc.identifier.doi10.1002/jbm.b.30206-
dc.contributor.localIdA00292-
dc.contributor.localIdA02216-
dc.contributor.localIdA04492-
dc.relation.journalcodeJ01267-
dc.identifier.eissn1552-4981-
dc.identifier.pmid15674839-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1002/jbm.b.30206/abstract-
dc.subject.keywordtitanium–silver alloys-
dc.subject.keywordfluoride-
dc.subject.keywordcorrosion resistance-
dc.subject.keywordpassive film-
dc.subject.keyworddental material-
dc.contributor.alternativeNameKim, Kyoung Nam-
dc.contributor.alternativeNameShim, Hyung Min-
dc.contributor.alternativeNameHwang, Chung Ju-
dc.citation.volume73B-
dc.citation.number2-
dc.citation.startPage252-
dc.citation.endPage259-
dc.identifier.bibliographicCitationJOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, Vol.73B(2) : 252-259, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid40345-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Dental Biomaterials and Bioengineering (치과생체재료공학교실) > 1. Journal Papers
2. College of Dentistry (치과대학) > Dept. of Orthodontics (교정과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.