0 465

Cited 19 times in

Optimum electrode configuration for detection of leg movement using bio-impedance

DC Field Value Language
dc.contributor.author김덕원-
dc.contributor.author남기창-
dc.date.accessioned2017-05-04T07:34:24Z-
dc.date.available2017-05-04T07:34:24Z-
dc.date.issued2005-
dc.identifier.issn0967-3334-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/147482-
dc.description.abstractImpedances and joint angles were simultaneously measured during ankle and knee movements. The correlation coefficients of the joint angle and the impedance change from human leg movement were obtained using an electro-goniometer and a four-channel impedance measurement system. Because the impedance changes resulting from ankle and knee movements depended heavily on the electrode placement, we determined the optimum electrode configurations for those movements by searching for high correlation coefficients, large impedance changes and minimum interferences in ten subjects (age: 20 ± 4). Our optimum electrode configurations showed strong relationships between the ankle joint angle and lower leg impedance (correlation coefficient = −0.91 ± 0.06) and between the knee joint angle and knee impedance (correlation coefficient = 0.94 ± 0.04). The reproducibilities of the impedance changes of five subjects due to the ankle and knee were 6.3 ± 1.9% and 5.1 ± 1.7% for the optimum electrode pairs, respectively. We propose that this optimum electrode configuration would be useful for future studies involving the convenient measurement of leg movements by the impedance method.-
dc.description.statementOfResponsibilityrestriction-
dc.languageEnglish-
dc.publisherIOP Pub. Ltd.-
dc.relation.isPartOfPHYSIOLOGICAL MEASUREMENT-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAdult-
dc.subject.MESHAnkle Joint/physiology*-
dc.subject.MESHElectric Impedance*-
dc.subject.MESHElectrodes*-
dc.subject.MESHHumans-
dc.subject.MESHKnee Joint/physiology*-
dc.subject.MESHLeg/physiology-
dc.subject.MESHMale-
dc.subject.MESHMovement/physiology*-
dc.subject.MESHPhysical Examination/instrumentation-
dc.subject.MESHPhysical Examination/methods-
dc.subject.MESHPlethysmography, Impedance/instrumentation-
dc.subject.MESHPlethysmography, Impedance/methods*-
dc.subject.MESHRange of Motion, Articular/physiology*-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHSensitivity and Specificity-
dc.titleOptimum electrode configuration for detection of leg movement using bio-impedance-
dc.typeArticle-
dc.publisher.locationEngland-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.departmentDept. of Medical Engineering (의학공학교실)-
dc.contributor.googleauthorChul Gyu Song-
dc.contributor.googleauthorSoo Chan Kim-
dc.contributor.googleauthorKi Chang Nam-
dc.contributor.googleauthorDeok Won Kim-
dc.identifier.doi10.1088/0967-3334/26/2/006-
dc.contributor.localIdA00376-
dc.contributor.localIdA01242-
dc.relation.journalcodeJ02527-
dc.identifier.eissn1361-6579-
dc.identifier.pmid15798247-
dc.identifier.urlhttp://iopscience.iop.org/0967-3334/26/2/006/-
dc.subject.keywordangular change-
dc.subject.keywordimpedance change-
dc.subject.keywordleg movement-
dc.subject.keywordoptimum electrode configuration-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.alternativeNameNam, Ki Chang-
dc.citation.volume26-
dc.citation.number2-
dc.citation.startPageS59-
dc.citation.endPageS68-
dc.identifier.bibliographicCitationPHYSIOLOGICAL MEASUREMENT, Vol.26(2) : S59-S68, 2005-
dc.date.modified2017-05-04-
dc.identifier.rimsid40262-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.