0 543

Cited 15 times in

Semi-automated counting method of axons in transmission electron microscopic images.

DC Field Value Language
dc.contributor.author김찬윤-
dc.date.accessioned2017-02-24T03:17:48Z-
dc.date.available2017-02-24T03:17:48Z-
dc.date.issued2016-
dc.identifier.issn1463-5216-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/146303-
dc.description.abstractOBJECTIVE: To evaluate the accuracy of a new semi-automated method for counting axons in transmission electron microscopic (TEM) images. PROCEDURES: Optic nerve cross sections were obtained from both eyes of Sprague Dawley rats after unilateral induction of chronic ocular hypertension. TEM images (3000× magnification) of cross sections were evaluated by both semi-automated and manual counting methods. The semi-automated counting method was performed using ImageJ software after simple image optimization, and the resulting estimate of axon damage was compared with semiquantitative damage grading scale from light microscopic (LM) images. RESULTS: Axon counts obtained from the semi-automated method were strongly correlated with those obtained from the manual counting method (Pearson's correlation coefficient r = 0.996, P < 0.001) and from the full manual count from LM images (Spearman's ρ = 0.973, P < 0.001). The semi-automated method measured axonal damage with an error of 0.94 ± 3.16% (mean ± standard deviation), with worse axonal damage associated with greater error. Interobserver and intra-observer variability in axons counts were low (Spearman's ρ = 0.999, P < 0.005). The results of the semi-automated counting method were highly correlated with semiquantitative damage grading scale (Spearman's ρ = 0.965, P < 0.001). CONCLUSION: Results of our semi-automated method for counting axons in TEM images were strongly correlated with those of conventional counting methods and showed excellent reproducibility.-
dc.description.statementOfResponsibilityrestriction-
dc.format.extent29~37-
dc.languageEnglish-
dc.publisherBlackwell Science-
dc.relation.isPartOfVETERINARY OPHTHALMOLOGY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHAutomation-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHIntraocular Pressure-
dc.subject.MESHMicroscopy, Electron, Transmission-
dc.subject.MESHMicrospheres-
dc.subject.MESHObserver Variation-
dc.subject.MESHOptic Nerve/cytology*-
dc.subject.MESHRats-
dc.subject.MESHRats, Sprague-Dawley-
dc.subject.MESHTime Factors-
dc.titleSemi-automated counting method of axons in transmission electron microscopic images.-
dc.typeArticle-
dc.publisher.locationEngland-
dc.contributor.collegeCollege of Medicine-
dc.contributor.departmentDept. of Ophthalmology-
dc.contributor.googleauthorChan Yun Kim-
dc.contributor.googleauthorSeungsoo Rho-
dc.contributor.googleauthorNaeun Lee-
dc.contributor.googleauthorChang-Kyu Lee-
dc.contributor.googleauthorYoungje Sung-
dc.identifier.doi10.1111/vop.12247-
dc.contributor.localIdA01035-
dc.relation.journalcodeJ02898-
dc.identifier.eissn1463-5224-
dc.identifier.pmid25639186-
dc.identifier.urlhttp://onlinelibrary.wiley.com/doi/10.1111/vop.12247/abstract-
dc.subject.keywordaxon-
dc.subject.keywordexperimental model-
dc.subject.keywordglaucoma-
dc.subject.keywordocular hypertension-
dc.subject.keywordsemi-automated counting-
dc.subject.keywordtransmission electron microscopy-
dc.contributor.alternativeNameKim, Chan Yun-
dc.contributor.affiliatedAuthorKim, Chan Yun-
dc.citation.volume19-
dc.citation.number1-
dc.citation.startPage29-
dc.citation.endPage37-
dc.identifier.bibliographicCitationVETERINARY OPHTHALMOLOGY, Vol.19(1) : 29-37, 2016-
dc.date.modified2017-02-24-
dc.identifier.rimsid53039-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.