196 329

Cited 0 times in

Quantitative assessment and ligament traceability of volume isotropic turbo spin echo acquisition (VISTA) ankle magnetic resonance imaging : fat suppression versus without fat suppression

DC Field Value Language
dc.contributor.author조경은-
dc.date.accessioned2017-01-26T05:40:24Z-
dc.date.available2017-01-26T05:40:24Z-
dc.date.issued2015-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/145706-
dc.descriptionDept. of Medicine/석사-
dc.description.abstractObjective: To compare the image quality and ligament traceability in ankle images obtained using Volume Isotropic Turbo Spin Echo Acquisition (VISTA) MRI with and without fat suppression.Materials and Methods: The signal-to-noise ratios (SNRs) in images from a phantom and from the ankle of a volunteer were compared. Ten ankles from 10 non-symptomatic volunteers were imaged for comparisons of contrast ratio (CR) and ligament traceability. All examinations were performed using VISTA sequences with and without fat suppression on a 3T MRI scanner. The SNRs were obtained from images with subjects and without subjects (noise-only). Contrast ratios from images of the 10 ankles were acquired between fluid and tendon (F-T), F-cartilage (C), F-ligament (L), fat (f)-T, f-C and f-L. Two musculoskeletal radiologists independently scored the traceability of 7 ligaments, in sagittal, axial and coronal images respectively, based on a 4-point scale (1 as not traceable through 4 as clearly traceable). The Wilcoxon signed-rank test was used to compare the CR. Fisher''s exact test and Pearson''s chi-squared test were used to compare the ligament traceability.Results: The SNRs did not differ significantly between the two sequences except in bone marrow. VISTA Spectral Attenuated Inversion Recovery (SPAIR) showed the higher CR only in F-T (p=0.04), whereas VISTA showed higher CR in f-T (p=0.005), f-C (p=0.005) and f-L (p=0.005). The calcaneofibular ligament traceability with VISTA was superior to that obtained with VISTA SPAIR (p < 0.05) in all planes.Conclusions: VISTA showed significant superiority to VISTA SPAIR in tracing CFL due to the superior CR between fat and ligament-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.publisherGraduate School, Yonsei University-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.titleQuantitative assessment and ligament traceability of volume isotropic turbo spin echo acquisition (VISTA) ankle magnetic resonance imaging : fat suppression versus without fat suppression-
dc.title.alternative발목관절 VISTA 자기공명영상에서 정량평가와 인대의 traceability : 지방억제 대 비지방억제기법-
dc.typeThesis-
dc.contributor.alternativeNameCho, Kyung Eun-
dc.type.localThesis-
Appears in Collections:
1. College of Medicine (의과대학) > Others (기타) > 2. Thesis

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.