302 342

Cited 0 times in

Hemodynamic changes, atrial remodeling and deposits of atrial natriuretic peptide in patients with atrial fibrillation are associated with clinical outcome of the maze operation

Other Titles
 심방 세동 환자에서 Atrial natriuretic peptide 의 축적과 심방의 변성 및 혈역동학적 변화와 maze 수술 이후 임상적 예후와의 관련성 
Authors
 박준범 
Department
 Dept. of Internal Medicine (내과학교실) 
Issue Date
2015
Description
Dept. of Medicine/박사
Abstract
Background: Isolated atrial amyloid (IAA) deposition in the left atrium (LA) is associated with atrial fibrillation (AF), and the maintenance of AF results in remodeling of the atrial substrate. However, there is no direct evidence of an association between atrial deposition of atrial natriuretic peptide (ANP) and atrial amyloids in patients with AF, and the clinical implications of this after the maze operation have not been investigated.Methods: Twenty left atrial appendage (LAA) tissues were acquired during mitral valve surgery and the maze operation. All tissues were stained with Congo red under polarized light to detect amyloids, and the area of amyloid deposits was quantified using Image Pro. ANP level was evaluated by Western blotting. And we quantified the protein expression of endocardial functions (endocardial nitric oxide [eNOS], phosphorylated eNOS [Phospho-eNOS]), intercellular adhesion molecule-1 (ICAM-1) and thrombotic factors (von Willebrand factor [vWF], a disintegrin and metalloproteinase with a thrombospondin type 1 motif, member 13 [ADAMTS13]) by Western blotting. Hemodynamic factors (pulmonary arterial pressure, PAP) were measured prior to the operation were analyzed according to the expression of ANP.Results: 1. ANP+ patients had a lower systolic PAP (p=0.04) than ANP- patients, and the presence of amyloid deposits was also negatively correlated (r=-0.6, p=0.008) with systolic PAP. 2. The expression level of eNOS (p=0.043), phospho-eNOS (p=0.013), vWF (p=0.031) and ICAM-1 (p=0.013) were lower in tissue with ANP expression (ANP+) than ANP- tissues. 3. More amyloid deposits were detected in ANP+ tissue than ANP- tissue (p=0.002). 4. Recurrence of AF after the maze operation was higher in ANP+ patients than ANP- patients (p=0.033), and all recurrence occurred within 150 days. ANP+ status was significantly associated with the recurrence of AF after
maze (p=0.005) even after adjusting for age, sex, and LA volume for a mean of 362.3±473.8 days (maximum 1,565 days).Conclusions: Atrial deposits of ANP showed a negative correlation with PAP, and reflected the presence of more atrial amyloid deposits. Deposition of ANP was strongly associated with decreased endocardial function and expression of intercellular adhesion molecule. Finally, expression of ANP was significantly associated with AF recurrence after the maze operation.
Files in This Item:
T013426.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 3. Dissertation
Yonsei Authors
Park, Jun Beom(박준범)
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/145614
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links