221 400

Cited 3 times in

Evaluation of a Bio-impedance Method for Measuring Human Arm Movement

DC Field Value Language
dc.contributor.author김덕원-
dc.date.accessioned2016-05-16T11:27:02Z-
dc.date.available2016-05-16T11:27:02Z-
dc.date.issued2002-
dc.identifier.issn0513-5796-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/144577-
dc.description.abstractThis study proposes a new method for measuring upper limb movement using a bio-impedance technique. Bio-impedance and joint angle were simultaneously measured during the wrist and elbow movements of 12 normal subjects. The joint angles of the wrist and elbow were estimated by measuring the bio-impedances of the forearm and upper arm, respectively. Although the measured bio-impedances on upper limbs varied among individuals, changes in the bio-impedances and joint angles of the wrist and elbow during their extension and flexion were very highly correlated, having correlation coefficients of 0.96 ± 0.04 and -0.98 ± 0.02, respectively. The reproducibilities of wrist and elbow bio-impedance changes were 2.1 ± 1.0% and 1.8 ± 1.0%, respectively. Since the proposed method is not restricted by size or the duration of measurements, it is expected to be useful for the analysis of athletic movement.-
dc.description.statementOfResponsibilityopen-
dc.format.extent637~643-
dc.relation.isPartOfYONSEI MEDICAL JOURNAL-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHElbow/physiology*-
dc.subject.MESHElectric Impedance-
dc.subject.MESHHumans-
dc.subject.MESHMovement-
dc.subject.MESHReproducibility of Results-
dc.subject.MESHWrist/physiology*-
dc.titleEvaluation of a Bio-impedance Method for Measuring Human Arm Movement-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthorJong Chan Kim-
dc.contributor.googleauthorSoo Chan Kim-
dc.contributor.googleauthorKi Chang Nam-
dc.contributor.googleauthorSeon Hui Ahn-
dc.contributor.googleauthorMignon Park-
dc.contributor.googleauthorDeok Won Kim-
dc.identifier.doi10.3349/ymj.2002.43.5.637-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00376-
dc.relation.journalcodeJ02813-
dc.identifier.eissn1976-2437-
dc.identifier.pmid12402378-
dc.subject.keywordBio-impedance-
dc.subject.keywordbio-dynamics-
dc.subject.keywordupper limb movement-
dc.subject.keywordwrist angl-
dc.subject.keywordelbow angle-
dc.contributor.alternativeNameKim, Deok Won-
dc.contributor.affiliatedAuthorKim, Deok Won-
dc.rights.accessRightsfree-
dc.citation.volume43-
dc.citation.number5-
dc.citation.startPage637-
dc.citation.endPage643-
dc.identifier.bibliographicCitationYONSEI MEDICAL JOURNAL, Vol.43(5) : 637-643, 2002-
dc.identifier.rimsid51264-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.