0 515

Cited 0 times in

Effect of microkeratome suction duration on corneal flap thickness and incision angle

DC Field Value Language
dc.contributor.author김응권-
dc.contributor.author서경률-
dc.date.accessioned2016-05-16T11:24:43Z-
dc.date.available2016-05-16T11:24:43Z-
dc.date.issued2002-
dc.identifier.issn1081-597X-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/144491-
dc.description.abstractTo determine the effect of suction duration on corneal flap thickness and incision angle of the cut margin created by a microkeratome in a porcine eye. Thirty porcine eyes were randomly assigned to three groups according to different suction duration: group 1 (10 sec), group 2 (35 sec), and group 3 (60 sec). The Hansatome microkeratome with a #160 plate and 8.5-mm-diameter suction ring was used to create a corneal flap with a diameter of 8.5 millimeters. Corneal flap thickness was measured by automated ultrasonic pachymetry, and the incision angle was assessed by measuring the angle of a sagittal section of the cornea using image analysis software. Mean corneal flap thickness in groups 1 (10 sec), 2 (35 sec), and 3 (60 sec) was 87.8 +/- 22.0 microm, 116.0 +/- 7.0 microm, and 127.2 +/- 16.8 microm, respectively. There was a statistically significant difference between groups 1 (10 sec) and 2 (35 sec) (P=.005) and groups 1 and 3 (P=.004). The mean incision angle in groups 1, 2, and 3 was 34.8 +/- 9.0 degrees, 44.4 +/- 16.1 degrees, and 48.24 +/- 15.3 degrees, respectively. A statistically significant difference was found between groups 1 (10 sec) and 2 (35 sec) (P=.044) and groups 1 (10 sec) and 3 (60 sec) (P<.001). In laser in situ keratomileusis in porcine eyes, an increase in suction duration resulted in a thicker flap and greater incision angle.-
dc.description.statementOfResponsibilityopen-
dc.format.extent715~719-
dc.relation.isPartOfJOURNAL OF REFRACTIVE SURGERY-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAnimals-
dc.subject.MESHCornea/surgery*-
dc.subject.MESHCorneal Topography-
dc.subject.MESHKeratomileusis, Laser In Situ*-
dc.subject.MESHMicroscopy, Video-
dc.subject.MESHOphthalmologic Surgical Procedures*-
dc.subject.MESHSuction*-
dc.subject.MESHSurgical Flaps/pathology*-
dc.subject.MESHSwine-
dc.subject.MESHTime Factors-
dc.titleEffect of microkeratome suction duration on corneal flap thickness and incision angle-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Ophthalmology (안과학)-
dc.contributor.googleauthorKyoung Yul Seo-
dc.contributor.googleauthorXiu H. Wan-
dc.contributor.googleauthorJae W. Jang-
dc.contributor.googleauthorJae Bum Lee-
dc.contributor.googleauthorMoon J. Kim-
dc.contributor.googleauthorEung Kweon Kim-
dc.identifier.doi10.3928/1081-597X-20021101-08-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00831-
dc.contributor.localIdA01870-
dc.relation.journalcodeJ01730-
dc.identifier.pmid12458865-
dc.identifier.urlhttp://search.proquest.com/docview/220136436/fulltext?accountid=15179-
dc.contributor.alternativeNameKim, Eung Kweon-
dc.contributor.alternativeNameSeo, Kyuong Yul-
dc.contributor.affiliatedAuthorKim, Eung Kweon-
dc.contributor.affiliatedAuthorSeo, Kyuong Yul-
dc.rights.accessRightsnot free-
dc.citation.volume18-
dc.citation.number6-
dc.citation.startPage715-
dc.citation.endPage719-
dc.identifier.bibliographicCitationJOURNAL OF REFRACTIVE SURGERY, Vol.18(6) : 715-719, 2002-
dc.identifier.rimsid49753-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Ophthalmology (안과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.