Cited 34 times in
Effect of microkeratome suction duration on corneal flap thickness and incision angle
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 서경률 | - |
dc.date.accessioned | 2016-05-16T11:24:43Z | - |
dc.date.available | 2016-05-16T11:24:43Z | - |
dc.date.issued | 2002 | - |
dc.identifier.issn | 1081-597X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/144491 | - |
dc.description.abstract | To determine the effect of suction duration on corneal flap thickness and incision angle of the cut margin created by a microkeratome in a porcine eye. Thirty porcine eyes were randomly assigned to three groups according to different suction duration: group 1 (10 sec), group 2 (35 sec), and group 3 (60 sec). The Hansatome microkeratome with a #160 plate and 8.5-mm-diameter suction ring was used to create a corneal flap with a diameter of 8.5 millimeters. Corneal flap thickness was measured by automated ultrasonic pachymetry, and the incision angle was assessed by measuring the angle of a sagittal section of the cornea using image analysis software. Mean corneal flap thickness in groups 1 (10 sec), 2 (35 sec), and 3 (60 sec) was 87.8 +/- 22.0 microm, 116.0 +/- 7.0 microm, and 127.2 +/- 16.8 microm, respectively. There was a statistically significant difference between groups 1 (10 sec) and 2 (35 sec) (P=.005) and groups 1 and 3 (P=.004). The mean incision angle in groups 1, 2, and 3 was 34.8 +/- 9.0 degrees, 44.4 +/- 16.1 degrees, and 48.24 +/- 15.3 degrees, respectively. A statistically significant difference was found between groups 1 (10 sec) and 2 (35 sec) (P=.044) and groups 1 (10 sec) and 3 (60 sec) (P<.001). In laser in situ keratomileusis in porcine eyes, an increase in suction duration resulted in a thicker flap and greater incision angle. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 715~719 | - |
dc.relation.isPartOf | JOURNAL OF REFRACTIVE SURGERY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | Animals | - |
dc.subject.MESH | Cornea/surgery* | - |
dc.subject.MESH | Corneal Topography | - |
dc.subject.MESH | Keratomileusis, Laser In Situ* | - |
dc.subject.MESH | Microscopy, Video | - |
dc.subject.MESH | Ophthalmologic Surgical Procedures* | - |
dc.subject.MESH | Suction* | - |
dc.subject.MESH | Surgical Flaps/pathology* | - |
dc.subject.MESH | Swine | - |
dc.subject.MESH | Time Factors | - |
dc.title | Effect of microkeratome suction duration on corneal flap thickness and incision angle | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | Kyoung Yul Seo | - |
dc.contributor.googleauthor | Xiu H. Wan | - |
dc.contributor.googleauthor | Jae W. Jang | - |
dc.contributor.googleauthor | Jae Bum Lee | - |
dc.contributor.googleauthor | Moon J. Kim | - |
dc.contributor.googleauthor | Eung Kweon Kim | - |
dc.identifier.doi | 10.3928/1081-597X-20021101-08 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01870 | - |
dc.relation.journalcode | J01730 | - |
dc.identifier.pmid | 12458865 | - |
dc.identifier.url | http://search.proquest.com/docview/220136436/fulltext?accountid=15179 | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Seo, Kyuong Yul | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Seo, Kyuong Yul | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 18 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 715 | - |
dc.citation.endPage | 719 | - |
dc.identifier.bibliographicCitation | JOURNAL OF REFRACTIVE SURGERY, Vol.18(6) : 715-719, 2002 | - |
dc.identifier.rimsid | 49753 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.