0 407

Cited 35 times in

Clinical evaluation of compression ratios using JPEG-2000 on computed radiography chest images

DC Field Value Language
dc.contributor.author유선국-
dc.date.accessioned2016-05-16T11:08:32Z-
dc.date.available2016-05-16T11:08:32Z-
dc.date.issued2002-
dc.identifier.issn0897-1889-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/143881-
dc.description.abstractThe efficient compression of radiographic images is of importance for improved storage and network utilization in support of picture archiving and communication systems (PACS) applications. The DICOM Working Group 4 adopted JPEG2000 as an additional compression standard in Supplement 61 over the existing JPEG. The wavelet-based JPEG2000 can achieve higher compression ratios with less distortion than the Discrete Cosine Transform (DCT)-based JPEG algorithm. However, the degradation of JPEG2000-compressed computed radiography (CR) chest images has not been tested comprehensively clinically. The authors evaluated the diagnostic quality of JPEG2000-compressed CR chest images with compression ratios from 5:1 to 200:1. An ROC (receiver operating characteristic analysis) and t test were performed to ascertain clinical performance using the JPEG2000-compressed images. The authors found that compression ratios as high as 20:1 can be utilized without affecting lesion detectability. Significant differences between the original and the compressed CR images were not recognized up to compression ratio of 50:1 within a confidence level of 99%.-
dc.description.statementOfResponsibilityopen-
dc.format.extent78~83-
dc.relation.isPartOfJOURNAL OF DIGITAL IMAGING-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHAlgorithms*-
dc.subject.MESHHumans-
dc.subject.MESHImage Processing, Computer-Assisted-
dc.subject.MESHROC Curve-
dc.subject.MESHRadiography, Thoracic*-
dc.subject.MESHRadiology Information Systems*-
dc.subject.MESHTomography, X-Ray Computed*-
dc.titleClinical evaluation of compression ratios using JPEG-2000 on computed radiography chest images-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Medical Engineering (의학공학)-
dc.contributor.googleauthorMin Mo Sung-
dc.contributor.googleauthorHee Joung Kim-
dc.contributor.googleauthorSun Kook Yoo-
dc.contributor.googleauthorByoung Wook Choi-
dc.contributor.googleauthorJi Eun Nam-
dc.contributor.googleauthorHye Sung Kim-
dc.contributor.googleauthorJae Hoon Lee-
dc.contributor.googleauthorHyung Sik Yoo-
dc.identifier.doi10.1007/s10278-002-0007-6-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA02471-
dc.relation.journalcodeJ01379-
dc.identifier.eissn1618-727X-
dc.identifier.pmid12297972-
dc.identifier.urlhttp://link.springer.com/article/10.1007/s10278-002-0007-6-
dc.subject.keywordCompression Ratio-
dc.subject.keywordDiscrete Cosine Transform-
dc.subject.keywordRadiography Chest-
dc.subject.keywordReceiver Operating Characteristic Analysis-
dc.subject.keywordRadiographic Image-
dc.contributor.alternativeNameYoo, Sun Kook-
dc.contributor.affiliatedAuthorYoo, Sun Kook-
dc.rights.accessRightsnot free-
dc.citation.volume15-
dc.citation.number2-
dc.citation.startPage78-
dc.citation.endPage83-
dc.identifier.bibliographicCitationJOURNAL OF DIGITAL IMAGING, Vol.15(2) : 78-83, 2002-
dc.identifier.rimsid37631-
dc.type.rimsART-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Medical Engineering (의학공학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.