260 458

Cited 0 times in

금속제 스텐트의 개통성에 영향을 미치는 악성 담도 폐쇄의 특징

Other Titles
 Features of Malignant Biliary Obstruction Affecting the Patency of Metallic Stents: A Multicenter Study 
Authors
 이동기  ;  김현수  ;  서정인  ;  임대욱  ;  백순구  ;  권상옥  ;  김호각  ;  박종재  ;  박상흠  ;  김진홍  ;  유병무  ;  노임환  ;  문영수 
Citation
 Korean Journal of Gastrointestinal Endoscopy (대한소화기내시경학회지), Vol.23(2) : 100-108, 2001 
Journal Title
Korean Journal of Gastrointestinal Endoscopy(대한소화기내시경학회지)
ISSN
 1225-7001 
Issue Date
2001
Keywords
금속제 스텐트 ; 악성 담도 폐쇄
Abstract
Background/Aims: Although metalic stents are established therapeutic options for the palliation of malignant biliary obstruction, it remains unclear which stricture or stent related factors affect the stent patency.
Methods: Metallic Wallstents (Microvasive, Boston-Scientific, MA, U.S.A.) were inserted endoscopically in 68 patients (mean age; 70.2±8.5, M:F=38:30) with malignant biliary obstruction. Patency rates were prospectively analyzed according to the characteristics of malignant strictures including length, morphologic type and degree of stricture. Furthermore, patient age, initial serum bilirubin level, the length of stent, the adequate expansion time, and the location of the distal
stent end were evaluated as possible factors affecting the stent patency. Stent patency was assessed using the survival analysis of the Kaplan-Meier estimation and Cox regression analysis.
Results: Median overall stent patency was 231 days and overall rate of stent occlusion was 41.2% (28/68). The causes of stent blockage were tumoral ingrowth in 23 patients (33.8%), distal overgrowth of the cancer in 3 (4.4%), proximal overgrowth in 1 (1.5%) and sludge incrustation in 1 patient (1.5%). No significant differences in metallic stent patency rates according to primary tumor type, length and morphologic type of stricture, and length and location of distal end of the stent were found. Log-rank test and multivariate regression analysis, however, demonstrated that the degree of stricture assessed by cannula or guidewire passage and the adequate expansion time of the stent are independent factors associated with long-term metallic stent patency.
Conclusions: Our study showed that early expansibility of the stent and easy passage of larger-caliber instruments over the stricture were favorable factors for long-term patency of the metallic stent.
Files in This Item:
T200201628.pdf Download
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Internal Medicine (내과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Dong Ki(이동기) ORCID logo https://orcid.org/0000-0002-0048-9112
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/143247
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links