Cited 0 times in
국산 다축성 입각기 및 유각기 동시제어 인공 슬관절의 평가
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김덕용 | - |
dc.contributor.author | 박창일 | - |
dc.contributor.author | 신지철 | - |
dc.date.accessioned | 2016-02-19T11:26:54Z | - |
dc.date.available | 2016-02-19T11:26:54Z | - |
dc.date.issued | 2001 | - |
dc.identifier.issn | 1225-584X | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/143165 | - |
dc.description.abstract | Objective: This study aimed to evaluate the kinematic data and energy consumption of domestic swing and stance phase (SNS) control knee assembly in transfemoral amputees. Method: Five male transfemoral amputees took prosthetic training of more than one week and evaluated with random applying 3 types of knee assembly; mechanical type, pneumatic type, and domestic SNS type. Kinematic data was obtained by the VICON 370 system (Oxford Metrics Ltd., UK.). Energy consumption was measured using a KB1-C (Aerosport Inc, U.S.A). Results: Domestic SNS type showed a significantly increased walking speed, cadence and step length compared with mechanical type and pneumatic type (p<0.05). Domestic SNS type showed a significantly increased maximal hip flexion and extension compared with mechanical type and pneumatic type (p<0.05). Domestic SNS type showed decreased peak knee flexion at swing phase and significantly increased peak knee extension at stance phase compard with mechanical type and pneumatic type (p<0.05). In energy consumption, the domestic SNS type tended to show a lower O2 cost and faster walking speed than the mechanical type and pneumatic type at free-walking. Conclusion: We concluded the domestic SNS type had more tendency toward a normal gait pattern and lower energy consumption compared with mechanical type and pneumatic type. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 1059~1068 | - |
dc.relation.isPartOf | Journal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 국산 다축성 입각기 및 유각기 동시제어 인공 슬관절의 평가 | - |
dc.title.alternative | Evaluation of Kinematic Data and Energy Consumption of Domestic Swing and Stance Phase Control Knee Assembly | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Rehabilitation Medicine (재활의학) | - |
dc.contributor.googleauthor | 박창일 | - |
dc.contributor.googleauthor | 신지철 | - |
dc.contributor.googleauthor | 배하석 | - |
dc.contributor.googleauthor | 김덕용 | - |
dc.contributor.googleauthor | 최용석 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00375 | - |
dc.contributor.localId | A01717 | - |
dc.contributor.localId | A02162 | - |
dc.relation.journalcode | J01803 | - |
dc.subject.keyword | Prosthesis | - |
dc.subject.keyword | Swing and stance phase control | - |
dc.subject.keyword | Kinematic data | - |
dc.subject.keyword | Energy consumption | - |
dc.contributor.alternativeName | Kim, Deog Young | - |
dc.contributor.alternativeName | Park, Chang Il | - |
dc.contributor.alternativeName | Shin, Ji Cheol | - |
dc.contributor.affiliatedAuthor | Kim, Deog Young | - |
dc.contributor.affiliatedAuthor | Park, Chang Il | - |
dc.contributor.affiliatedAuthor | Shin, Ji Cheol | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 25 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1059 | - |
dc.citation.endPage | 1068 | - |
dc.identifier.bibliographicCitation | Journal of the Korean Academy of Rehabilitation Medicine (대한재활의학회지), Vol.25(6) : 1059-1068, 2001 | - |
dc.identifier.rimsid | 39103 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.