358 488

Cited 0 times in

전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교

DC Field Value Language
dc.contributor.author김기덕-
dc.date.accessioned2016-02-19T11:20:13Z-
dc.date.available2016-02-19T11:20:13Z-
dc.date.issued2001-
dc.identifier.issn1229-8212-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/142920-
dc.description.abstractPurpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/supTM</SUP>. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.-
dc.description.statementOfResponsibilityopen-
dc.format.extent1~7-
dc.languageKorean-
dc.publisher대한구강악안면방사선학회-
dc.relation.isPartOfKorean Journal of Oral and Maxillofacial Radiology (대한구강악안면방사선학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.title전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교-
dc.title.alternativeComparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of General Dentistry (통합진료학)-
dc.contributor.googleauthor강복희-
dc.contributor.googleauthor김기덕-
dc.contributor.googleauthor박창서-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00332-
dc.relation.journalcodeJ02085-
dc.subject.keywordCT workstation-
dc.subject.keywordpersonal computer-
dc.subject.keywordreconstructed 3-dimensional CT image-
dc.contributor.alternativeNameKim, Kee Deog-
dc.contributor.affiliatedAuthorKim, Kee Deog-
dc.rights.accessRightsfree-
dc.citation.volume31-
dc.citation.number1-
dc.citation.startPage1-
dc.citation.endPage7-
dc.identifier.bibliographicCitationKorean Journal of Oral and Maxillofacial Radiology, Vol.31(1) : 1-7, 2001-
dc.identifier.rimsid39577-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.