65 174

Cited 0 times in

Mini-Wright Peak Flow Meter로 측정한 한국 성인의 최고호기유량의 정상치

Other Titles
 Peak Expiratory Flow in Normal Healthy Korean Subjects Measured by Mini-Wright Peak Flow Meter 
Authors
 김영삼 ; 안애란 ; 김성규 ; 오재준 ; 안철민 ; 장준 ; 김세규 
Citation
 Tuberculosis and Respiratory Diseases (결핵 및 호흡기질환), Vol.50(3) : 320~333, 2001 
Journal Title
 Tuberculosis and Respiratory Diseases  (결핵 및 호흡기질환) 
ISSN
 3780-0066 
Issue Date
2001
Abstract
Background: Peak expiratory flow (PEF) provides a simple, quantitative, and reproducible measure of the existence and severity of airflow obstructions. Peak flow meters are designed to monitor the condition asthma patients. There are many reports showing the normal predicted value of PEF in other countries. studies on healthy Korean adults have been performed in a relatively small sample number and a lower limit for the normal value was not reported. therefore, an attempt to provide normal predictive PEF value with a lower limit was made. Method : The PEF(Mini-Wright peak Flow Meter) measurements and spirometry were done in 233 men and 631 woman without history of respiratory disease. all subjects were non-smokers with no respiratory symptoms. the normal predictive value and its lower limit were developed by multiple regression analysis. The result was compared with regression equations in other reports. Results: The regression equation for the normal PEF predictive value(L/min) is 25.117+4.587×Age(year)-0.064×Age2+2.931×Height(cm) in men in men(R2=0.25), and 146.942-0.011×Age2+1.795×Height(cm)+0.836×Weight (kg) in women(R2=0.21). The regression equation for the lower limit of this value (L/min) is 25.117+4.587×Age(year)-0.064×Age2+1.936×Height (cm) in men, and 146.942-0.011×Age2+1.232× Height (cm)+0.481×Weight (kg) in women. The residuals were normally distributed. The PEF in Korean males was similar to those reported in British and Japanese subjects. The PEF in Korean females was similar to that in British subjects, But higher than the PEF in Japanese subjects. The lower limit of normal value was 71% of normal predictive PEF value in men and 76% in women. Conclusion: The normal predictive PEF value and its lower limit was measured from 233 male and 631 female asymptomatic, lifelong non-smoking participants. The normal predictive value was different from those of other studies on Korean subjects. Therefore, further studies are required.
URI
http://ir.ymlib.yonsei.ac.kr/handle/22282913/142420
Appears in Collections:
1. 연구논문 > 1. College of Medicine > Dept. of Internal Medicine
Yonsei Authors
사서에게 알리기
  feedback
Files in This Item:
T200102210.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse