Cited 0 times in
서로 다른 세 가지 비구면 일체형 인공수정체 삽입 수술 후 임상 결과의 비교
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김응권 | - |
dc.contributor.author | 김태임 | - |
dc.contributor.author | 서경률 | - |
dc.contributor.author | 이형근 | - |
dc.contributor.author | 정지원 | - |
dc.contributor.author | 정병훈 | - |
dc.date.accessioned | 2016-02-04T11:25:07Z | - |
dc.date.available | 2016-02-04T11:25:07Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/140380 | - |
dc.description.abstract | Purpose: We compared the clinical results after implantation of the newly-developed aspheric intraocular lens iSert 250 NC60 (Hoya Corporation Ltd., Tokyo, Japan) with 2 other types of widely used intraocular lenses, AcrySof IQ SN60WF (Alcon Laboratories, INC., Fort Worth, TX, USA) and TECNIS 1-piece ZCB00 (AMO Inc., Santa Ana, CA, USA). Methods: Seventy cataract eyes were implanted with 1 of 3 aspheric intraocular lenses (Hoya iSert 250 NC60, TECNIS 1-piece ZCB00 or AcrySof IQ SN60WF) by the same surgeon. Uncorrected vision, best corrected vision, spherical equivalent, higher order aberrations, and modulation transfer function were measured 1 and 3 months after the cataract surgery. Results: Uncorrected vision and best corrected vision were not significantly different among the 3 groups; however, eyes implanted with iSert250 NC60 showed more hyperopic-shifted postoperative spherical equivalents than expected compared to the other 2 groups. Total ocular aberrations and internal optics aberrations were similar among the 3 groups while the root mean square of the corneal aberrations showed differences. Eyes implanted with iSert 250 NC60 showed superior results in modulation transfer function compared with the other 2 groups in a majority of spatial frequencies 3 months postoperatively. Conclusions: The newly developed aspheric intraocular lens iSert 250 NC60 showed clinically equal results compared with 2 other verified intraocular lenses AcrySof IQ SN60WF and TECNIS 1-piece ZCB00 in vision, higher-order aberrations, and modulation transfer functions. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | 서로 다른 세 가지 비구면 일체형 인공수정체 삽입 수술 후 임상 결과의 비교 | - |
dc.title.alternative | Comparing Clinical Results after Intraocular Lens Implantation Surgery Using Three Other Aspheric Lenses | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | 정병훈 | - |
dc.contributor.googleauthor | 정지원 | - |
dc.contributor.googleauthor | 이형근 | - |
dc.contributor.googleauthor | 서경률 | - |
dc.contributor.googleauthor | 김응권 | - |
dc.contributor.googleauthor | 김태임 | - |
dc.identifier.doi | 10.3341/jkos.2015.56.4.541 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00831 | - |
dc.contributor.localId | A01080 | - |
dc.contributor.localId | A01870 | - |
dc.contributor.localId | A03303 | - |
dc.contributor.localId | A03736 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.subject.keyword | Aberration | - |
dc.subject.keyword | Cataract | - |
dc.subject.keyword | Intraocular lens | - |
dc.subject.keyword | Modulation transfer function | - |
dc.subject.keyword | Preloaded | - |
dc.contributor.alternativeName | Kim, Eung Kweon | - |
dc.contributor.alternativeName | Kim, Tae Im | - |
dc.contributor.alternativeName | Seo, Kyuong Yul | - |
dc.contributor.alternativeName | Lee, Hyung Keun | - |
dc.contributor.alternativeName | Jung, Ji Won | - |
dc.contributor.affiliatedAuthor | Kim, Eung Kweon | - |
dc.contributor.affiliatedAuthor | Kim, Tae Im | - |
dc.contributor.affiliatedAuthor | Seo, Kyuong Yul | - |
dc.contributor.affiliatedAuthor | Lee, Hyung Keun | - |
dc.contributor.affiliatedAuthor | Jung, Ji Won | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 56 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 541 | - |
dc.citation.endPage | 547 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.56(4) : 541-547, 2015 | - |
dc.identifier.rimsid | 51592 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.