Cited 0 times in
WCDMA 휴대전화 전자파가 인공심장 박동기 및이식형 제세동기에 미치는 영향
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김덕원 | - |
dc.date.accessioned | 2016-02-04T10:56:38Z | - |
dc.date.available | 2016-02-04T10:56:38Z | - |
dc.date.issued | 2015 | - |
dc.identifier.issn | 2287-5026 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/139322 | - |
dc.description.abstract | Reports show that global system for mobile communication (GSM) mobile phones, or two-generation (2G) mobile phones, could affect functions of pacemakers and implantable cardioverter defibrillators (ICDs). In this study, we evaluated the effects of radio frequency electromagnetic fields (RF-EMFs) emitted by wideband code division multiple access (WCDMA) mobile phones, which were third-generation (3G) mobile phones, on pacemakers and ICDs. Five pacemakers and three ICDs were subjected to in-vitro test using a ECG simulator. We used a WCDMA module (average power : 0.25 W, frequency band : 1950 MHz) instead of a real WCDMA mobile phone. To assess the effects of the WCDMA module on pacemakers and ICDs, each implantable device was placed in close proximity (within 3 mm) to the WCDMA module for 5 min. As a result, no effects were observed on the five pacemakers and three ICDs for the RF-EMFs emitted by the WCDMA module. Because WCDMA mobile phones have the higher frequency band (1800-2200 MHz) and lower power output (0.01-0.25 W) than GSM moboile phone, the RF-EMFs emitted by WCDMA mobile phones do not affect patients with pacemaker or ICD. | - |
dc.description.statementOfResponsibility | open | - |
dc.format.extent | 148~154 | - |
dc.relation.isPartOf | Journal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지) | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.title | WCDMA 휴대전화 전자파가 인공심장 박동기 및이식형 제세동기에 미치는 영향 | - |
dc.title.alternative | Effects of Radio Frequency Electromagnetic Fields Emitted by WCDMA Mobile Phones on Pacemakers and ICDs | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Medical Engineering (의학공학) | - |
dc.contributor.googleauthor | 정재원 | - |
dc.contributor.googleauthor | 최수범 | - |
dc.contributor.googleauthor | 박지수 | - |
dc.contributor.googleauthor | 김덕원 | - |
dc.identifier.doi | 10.5573/ieie.2015.52.1.148 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00376 | - |
dc.relation.journalcode | J01784 | - |
dc.subject.keyword | WCDMA mobile phone | - |
dc.subject.keyword | Pacemaker | - |
dc.subject.keyword | Implantable Cardioverter Defibrillator | - |
dc.subject.keyword | Malfunction | - |
dc.contributor.alternativeName | Kim, Deok Won | - |
dc.contributor.affiliatedAuthor | Kim, Deok Won | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 52 | - |
dc.citation.number | 1 | - |
dc.citation.startPage | 148 | - |
dc.citation.endPage | 154 | - |
dc.identifier.bibliographicCitation | Journal of the Institute of Electronics and Information Engineers of Korea (전자공학회논문지), Vol.52(1) : 148-154, 2015 | - |
dc.identifier.rimsid | 45569 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.