Biomechanical Phenomena ; Decompression, Surgical/methods* ; Finite Element Analysis* ; Humans ; Intervertebral Disc/physiopathology ; Intervertebral Disc/surgery ; Laminectomy/methods* ; Lumbar Vertebrae/pathology ; Lumbar Vertebrae/physiopathology ; Lumbar Vertebrae/surgery* ; Male ; Middle Aged ; Models, Anatomic ; Osteotomy/methods* ; Range of Motion, Articular ; Stress, Mechanical ; Zygapophyseal Joint/pathology ; Zygapophyseal Joint/physiopathology ; Zygapophyseal Joint/surgery
Keywords
Lumbar spinal stenosis ; conventional laminectomy ; finite element model ; spinous process osteotomies
Abstract
PURPOSE: The purpose of this study was to evaluate and compare the biomechanical behavior of the lumbar spine after posterior decompression with the spinous process osteotomy (SPiO) technique or the conventional laminectomy (CL) technique using a finite element (FE) model.
MATERIALS AND METHODS: Three validated lumbar FE models (L2-5) which represented intact spine and two decompression models using SPiO and CL techniques at the L3-4 segment were developed. In each model, the ranges of motion, the maximal von Mises stress of the annulus fibrosus, and the intradiscal pressures at the index segment (L3-4) and adjacent segments (L2-3 and L4-5) under 7.5 Nm moments were analyzed. Facet contact forces were also compared among three models under the extension and torsion moments.
RESULTS: Compared to the intact model, the CL and SPiO models had increased range of motion and annulus stress at both the index segment (L3-4) and the adjacent segments under flexion and torsion. However, the SPiO model demonstrated a reduced range of motion and annulus stress than the CL model. Both CL and SPiO models had an increase of facet contact force at the L3-4 segment under the torsion moment compared to that of the intact model. Under the extension moment, however, three models demonstrated a similar facet contact force even at the L3-4 model.
CONCLUSION: Both decompression methods lead to postoperative segmental instability compared to the intact model. However, SPiO technique leads to better segmental stability compared to the CL technique.
Files in This Item:
T201500261.pdf Download
DOI
10.3349/ymj.2015.56.1.146
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
Yonsei Authors
Lee, Hwan Mo(이환모) ORCID logo https://orcid.org/0000-0002-5405-3832
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/139320
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links