Cited 0 times in
생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김덕원 | - |
dc.date.accessioned | 2015-07-15T17:14:43Z | - |
dc.date.available | 2015-07-15T17:14:43Z | - |
dc.date.issued | 2003 | - |
dc.identifier.issn | 1229-6287 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/114521 | - |
dc.description.abstract | This paper describes the possibility of analyzing gait pattern from the changes of the lower leg electrical impedance. This impedance was measured by the four-electrode method. Two current electrodes were applied to the thigh, knee, and foot., and two potential electrodes were applied to the lateral, medial, and posterior position of human leg. The correlation coefficients of the joint angle and the impedance change from human leg movement was obtained using a electrogoniometer and 4ch impedance measurement system developed in this study. We found the optimal electrode position for knee and ankle joint movements based on high correlation coefficient, least interference, and maximum magnitude of impedance change. The correlation coefficients of the ankle, knee, and the hip movements were -0.913, 0.984 and 0.823, respectively. From such features of the human leg impedance, it has been made clear that different movement patterns exhibit different impedance patterns and impedance level. This system showed feasibility that lower leg movement could be easily measured by impedance measurement system with a few skin-electrodes. | - |
dc.description.statementOfResponsibility | open | - |
dc.relation.isPartOf | 전기학회논문지 D | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | optimal electrode configuration | - |
dc.subject.MESH | impedance change | - |
dc.subject.MESH | knee movement | - |
dc.subject.MESH | ankle movement | - |
dc.subject.MESH | hip movement | - |
dc.subject.MESH | angular change | - |
dc.title | 생체 임피던스를 이용한 인체 하지운동 출을 위한 최적 전극위치 선정 | - |
dc.title.alternative | Optimal Electrode Selection for Detection of Human Leg Movement Using Bio-Impedance | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Medical Engineering (의학공학) | - |
dc.contributor.googleauthor | 송철규 | - |
dc.contributor.googleauthor | 윤대영 | - |
dc.contributor.googleauthor | 김덕원 | - |
dc.contributor.googleauthor | 김승찬 | - |
dc.contributor.googleauthor | 이동헌 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A00376 | - |
dc.relation.journalcode | J03252 | - |
dc.identifier.url | http://www.dbpia.co.kr/Journal/ArticleDetail/1096147 | - |
dc.subject.keyword | optimal electrode configuration | - |
dc.subject.keyword | impedance change | - |
dc.subject.keyword | knee movement | - |
dc.subject.keyword | ankle movement | - |
dc.subject.keyword | hip movement | - |
dc.subject.keyword | angular change | - |
dc.contributor.alternativeName | Kim, Deok Won | - |
dc.contributor.affiliatedAuthor | Kim, Deok Won | - |
dc.rights.accessRights | not free | - |
dc.citation.volume | 52D | - |
dc.citation.number | 8 | - |
dc.citation.startPage | 506 | - |
dc.citation.endPage | 509 | - |
dc.identifier.bibliographicCitation | 전기학회논문지 D, Vol.52D(8) : 506-509, 2003 | - |
dc.identifier.rimsid | 43905 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.