dc.description.abstractThe success of dental implant therapy relies mainly upon the presence and maintenance of bone adjacent to implant. An 1-year prospective study was performed, upon the patients who were diagnosed as having chronic adult periodontitis, and had been treated with dental implant. The purpose of this study was to measure the radiographic bone level changes proximal to Astra Tech Single Tooth Implants (ATST, Astra Tech AB, Mölndal, Sweden) with microthread and Astra Tech TiOblast Implant (ATTB) without microthread supporting fixed partial prosthesis. Measurements were used to determine mean marginal bone loss during the first year of loading, 17 subjects with its partial prosthesis supported by 37 implants were followed up for an 1-year period. The marginal bone loss of implants was positively correlated with the retention factor, microthread(Microthread™) in crestal area of ATST. The results were as follows. 1. The mean marginal bone loss of ATST was 0.226±0.395mm, while ATTB was 0.440±0.360mm. There was a statistically significant difference between ATST and ATTB (p<0.05). 2. The mean bone loss of the upper jaw fixtures was 0.269±0.265mm for ATST and 0.529±0.417mm for ATTB . There was a statistically significant difference between ATST and ATTB (p<0.05). In the lower jaw the corresponding figures were 0.167±0.231mm and 0.313±0.214mm, respectively. There was no significant difference between ATST and ATTB (p>0.05). 3. The mean bone loss of ATST was lower than that of ATTB at all sites according to bone quality. There was a statistically significant difference between ATST and ATTB at bone quality type III(p <0.05). In conclusion, the mean bone loss of ATST was smaller than that of ATTB . Therefore, the retention factor of crestal area, microthread (Microthread™) was effective to maintenance of marginal bone level around fixture.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJournal of Korean Academy of Periodontology (대한치주과학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHastra tech implant-
dc.subject.MESHmicrothread-
dc.subject.MESHmarginal bone level-
dc.subject.MESHradiographic evaluation-
dc.title임프란트 미세나사선이 주위골 수준변화에 미치는 영향에 대한 1년간의 전향적 비교 연구-
dc.title.alternativeAn 1year prospective comparative study evaluateing the effect of microthread on the maintenance of marginal bone level-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of Periodontology (치주과학)-
dc.contributor.googleauthor신동환-
dc.contributor.googleauthor조규성-
dc.contributor.googleauthor문익상-
dc.contributor.googleauthor박광호-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA01373-
dc.contributor.localIdA03810-
dc.relation.journalcodeJ01492-
dc.subject.keywordastra tech implant-
dc.subject.keywordmicrothread-
dc.subject.keywordmarginal bone level-
dc.subject.keywordradiographic evaluation-
dc.contributor.alternativeNameMoon, Ik Sang-
dc.contributor.alternativeNameCho, Kyoo Sung-
dc.contributor.affiliatedAuthorMoon, Ik Sang-
dc.contributor.affiliatedAuthorCho, Kyoo Sung-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number3-
dc.citation.startPage349-
dc.citation.endPage358-
dc.identifier.bibliographicCitationJournal of Korean Academy of Periodontology (대한치주과학회지), Vol.33(3) : 349-358, 2003-
dc.identifier.rimsid43877-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Periodontics (치주과학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.