Cited 0 times in
녹내장 환자에 있어 Visual Capacity Analyzer (ACV) 를 이용한 형태시적 대비 감도 검사의 재현성
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 성공제 | - |
dc.date.accessioned | 2015-07-15T17:11:16Z | - |
dc.date.available | 2015-07-15T17:11:16Z | - |
dc.date.issued | 2003 | - |
dc.identifier.issn | 0378-6471 | - |
dc.identifier.uri | https://ir.ymlib.yonsei.ac.kr/handle/22282913/114404 | - |
dc.description.abstract | PURPOSE: To determine the reproducibility of morphoscopic contrast sensitivity test values in the patients with primary open angle glaucoma using the Visual Capacity Analyzer (ACV) designed for assessing full visual performance including contrast sensitivity. METHODS: Morphoscopic contrast sensitivity was measured in each five glaucomatous eyes. The measurement was repeated 5 times under two different luminance level of screen (maximum and 3 cd/m2). RESULTS: Under maximum luminance background, the coefficients of variation (CV) and the reliability coefficients (RC) for the spatial frequencies examined in this study ranged from 2.1% to 29.3%, from 92.1% to 100.0%, respectively. Under 3cd/m2 luminance level of screen, the CV ranged from 2.7% to 32.0%, and the RC ranged from 90.7% to 99.9%. CONCLUSIONS: The results indicates that for the spatial frequencies examined, the morphoscopic contrast sensitivity test using ACV shows good reproducibility in glaucomatous patients. | - |
dc.description.statementOfResponsibility | open | - |
dc.format | application/pdf | - |
dc.relation.isPartOf | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY | - |
dc.rights | CC BY-NC-ND 2.0 KR | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/2.0/kr/ | - |
dc.subject.MESH | contrast sensitivity test | - |
dc.subject.MESH | glaucoma | - |
dc.subject.MESH | reproducibility | - |
dc.subject.MESH | visual capacity analyzer | - |
dc.title | 녹내장 환자에 있어 Visual Capacity Analyzer (ACV) 를 이용한 형태시적 대비 감도 검사의 재현성 | - |
dc.title.alternative | Reproducibility of Morphoscopic Contrast Sensitivity Obtained with the Visual Capacity Analyzer in Glaucoma Patients | - |
dc.type | Article | - |
dc.contributor.college | College of Medicine (의과대학) | - |
dc.contributor.department | Dept. of Ophthalmology (안과학) | - |
dc.contributor.googleauthor | 고일환 | - |
dc.contributor.googleauthor | 성공제 | - |
dc.admin.author | false | - |
dc.admin.mapping | false | - |
dc.contributor.localId | A01946 | - |
dc.relation.journalcode | J01838 | - |
dc.identifier.eissn | 2092-9374 | - |
dc.subject.keyword | contrast sensitivity test | - |
dc.subject.keyword | glaucoma | - |
dc.subject.keyword | reproducibility | - |
dc.subject.keyword | visual capacity analyzer | - |
dc.contributor.alternativeName | Seong, Gong Je | - |
dc.contributor.affiliatedAuthor | Seong, Gong Je | - |
dc.rights.accessRights | free | - |
dc.citation.volume | 44 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 1341 | - |
dc.citation.endPage | 1345 | - |
dc.identifier.bibliographicCitation | JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, Vol.44(6) : 1341-1345, 2003 | - |
dc.identifier.rimsid | 47283 | - |
dc.type.rims | ART | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.