858 664

Cited 0 times in

응급 전산화단층촬영에서 조영제 사용에 따른 신독성

DC Field Value Language
dc.contributor.author김승호-
dc.date.accessioned2015-07-15T17:06:48Z-
dc.date.available2015-07-15T17:06:48Z-
dc.date.issued2003-
dc.identifier.issn1226-4334-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114252-
dc.description.abstractPurpose: In the last 30 years, there has been a markedly increased use of iodinated contrast agents in diagnostic and interventional radiological procedures. Due to the possible side effect of nephrotoxicity of these radiocontrast agents, we investigated the incidence of nephrotoxicity and attempted to identify the patient groups at higher risk for contrast nephrotoxicity among the patients who underwent emergency computerized tomography. Methods: We reviewed the medical records of 1,572 patients who had undergone contrast computerized tomography at the Emergency Center, Yonsei Medical Center, from January to May 2002. We defined contrast nephrotoxicity as any increase in the creatinine value of more than 0.5 mg/dL (44mol/L) or 25% compared to the vaseline value. Results: We found 21 patients (1.3%) who met the criterion for contrast nephrotoxicity: 13 patients with normal renal function, and 8 patients with a higher than normal creatinine value before contrast-enhanced computerized tomography. The incidence of contrast nephrotoxicity in the patient group with normal renal function was 0.8% (13/1551), compared to 38.1% (8/21) in the pre-existing renal insufficiency group. There were no statistical differences on the amounts of dye used and the frequencies of risk factors for contrast nephrotoxicity between the patients in pre-existing renal insufficiency group who developed nephrotoxicity and who did not. The renal function of all patients returned to the baseline value without dialysis or renal replacement therapy. Conclusion: Pre-existing renal insufficiency is the most important risk factor for contrast nephrotoxicity. We need to take precautions and to have a proper protocol for the prevention of contrast nephrotoxicity in emergency care.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.relation.isPartOfJournal of the Korean Society of Emergency Medicine (대한응급의학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHContrast nephrotoxicity-
dc.subject.MESHContrast media-
dc.subject.MESHRenal failure-
dc.title응급 전산화단층촬영에서 조영제 사용에 따른 신독성-
dc.title.alternativeContrast Nephrotoxicity Associated with Emergency CT scans-
dc.typeArticle-
dc.contributor.collegeCollege of Medicine (의과대학)-
dc.contributor.departmentDept. of Emergency Medicine (응급의학)-
dc.contributor.googleauthor조영순-
dc.contributor.googleauthor정태녕-
dc.contributor.googleauthor김승호-
dc.contributor.googleauthor손대곤-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00667-
dc.relation.journalcodeJ01868-
dc.subject.keywordContrast nephrotoxicity-
dc.subject.keywordContrast media-
dc.subject.keywordRenal failure-
dc.contributor.alternativeNameKim, Seung Ho-
dc.contributor.affiliatedAuthorKim, Seung Ho-
dc.rights.accessRightsfree-
dc.citation.volume14-
dc.citation.number2-
dc.citation.startPage157-
dc.citation.endPage161-
dc.identifier.bibliographicCitationJournal of the Korean Society of Emergency Medicine (대한응급의학회지), Vol.14(2) : 157-161, 2003-
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Emergency Medicine (응급의학교실) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.