0 475

Cited 19 times in

Lateral J-plate fixation in comminuted intercondylar fracture of the humerus

Authors
 Kyu Hyun Yang  ;  Hui Wan Park  ;  Sung Hoon Jung  ;  Sung Jin Park 
Citation
 ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, Vol.123(5) : 234-238, 2003 
Journal Title
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY
ISSN
 0936-8051 
Issue Date
2003
MeSH
Adolescent ; Adult ; Bone Plates* ; Elbow Joint/physiopathology ; Female ; Follow-Up Studies ; Fracture Fixation, Internal/methods* ; Humans ; Humeral Fractures/surgery* ; Male ; Middle Aged ; Prospective Studies ; Range of Motion, Articular ; Time Factors ; Treatment Outcome
Keywords
Humerus ; Intercondylar fracture ; Lateral plate
Abstract
BACKGROUND:
Anatomical reduction and rigid internal fixation of the articular surface is key for functional recovery in types C2 and C3 (AO classification) fractures of the distal humerus. Since these fractures are associated with varying degrees of comminution in both the medial and lateral columns, rigid fixation of both columns is necessary for early mobilization of the elbow joint.
METHODS:
We performed a prospective study of the lateral J-plating technique in 17 patients with comminuted intercondylar fracture of the humerus. There were 9 type C2 and 8 type C3 fractures by the AO/ASIF classification. A lateral J-plate was applied along the lateral aspect of lateral column, and the lag screws were inserted into the medial column through the plate hole. A medial reconstruction plate was selectively applied on the posterior aspect of medial column.
RESULTS:
All fractures united by 18.7 weeks on average (range 10-28 weeks). Seven patients presented with limitation of motion of the elbow joint, and 5 of them underwent arthrolysis and excision of the heterotopic ossification. The final range of motion of the elbow joint was flexion contracture of 16 deg to further flexion of 121 deg on average. Functional results were excellent in 9 cases, good in 6, fair in 1, and poor in 1 according to Murray's criteria.
CONCLUSION:
Lateral J-plating with selective augmentation of the medial column provided sufficient rigidity and good clinical results.
Full Text
http://link.springer.com/article/10.1007/s00402-003-0508-x
DOI
10.1007/s00402-003-0508-x
Appears in Collections:
1. College of Medicine (의과대학) > Dept. of Orthopedic Surgery (정형외과학교실) > 1. Journal Papers
Yonsei Authors
Yang, Kyu Hyun(양규현) ORCID logo https://orcid.org/0000-0001-7183-588X
URI
https://ir.ymlib.yonsei.ac.kr/handle/22282913/114224
사서에게 알리기
  feedback

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

Browse

Links