Cited 0 times in

개인용 컴퓨터에서 재구성한 3차원 전산화단층영상의 두부계측 재현성

DC Field Value Language
dc.contributor.author김기덕-
dc.contributor.author전국진-
dc.date.accessioned2015-07-15T17:05:16Z-
dc.date.available2015-07-15T17:05:16Z-
dc.date.issued2003-
dc.identifier.issn1229-8212-
dc.identifier.urihttps://ir.ymlib.yonsei.ac.kr/handle/22282913/114200-
dc.description.abstractPURPOSE : The purpose of this study was to report the reproducibility of intra-observer and inter-observer consistency of cephalometric measurements using three-dimensional (3D) computed tomography (CT), and the degree of difference of the cephalometric measurements. MATERIALS AND METHODS : CT images of 16 adult patients with normal class I occlusion were sent to personal computer and reconstructed into 3D images using V-Works 3.5TM (Cybermed Inc., Seoul, Korea). With the internal program of V-Works 3.5TM, 12 landmarks on regular cephalograms were transformed into 21 analytic categories and measured by 2 observers and in addition, one of the observers repeated their measurements. Intra-observer difference was calculated using paired t-test, and inter-observer by two sample test. RESULTS : There were significant differences in the intra-observer measurements (p<0.05) in four of the categories which included ANS-Me, ANS-PNS, Cdl-Go (Lt), GoL-GoR, but with the exception of Cdl-Go (Lt), ZmL-ZmR, Zyo-Zyo, the average differences were within 2 mm of each other. The inter-observer observations also showed significant differences in the measurements of the ZmL-ZmR and Zyo-Zyo categories (p<0.05). With the exception of the Cdl-Me (Rt), ZmL-ZmR, Zyo-Zyo categories, the average differences between the two observers were within 2 mm, but the ZmL-ZmR and Zyo-Zyo values differed greatly with values of 8.10 and 19.8 mm respectively. CONCLUSION : In general, 3D CT images showed greater accuracy and reproducibility, with the exception of suture areas such as Zm and Zyo, than regular cephalograms in orthodontic measurements, showing differences of less than 2 mm, therefore 3D CT images can be useful in cephalometric measurements and treatment planning.-
dc.description.statementOfResponsibilityopen-
dc.formatapplication/pdf-
dc.languageKorean-
dc.publisher대한구강악안면방사선학회-
dc.relation.isPartOfKorean Journal of Oral and Maxillofacial Radiology (대한구강악안면방사선학회지)-
dc.rightsCC BY-NC-ND 2.0 KR-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/2.0/kr/-
dc.subject.MESHtomography-
dc.subject.MESHx-ray computed-
dc.subject.MESHcephalometry-
dc.subject.MESHreproducibility of results-
dc.title개인용 컴퓨터에서 재구성한 3차원 전산화단층영상의 두부계측 재현성-
dc.title.alternativeReproducibilities of cephalometric measurements of three-dimensional CT images reconstructed in the personal computer-
dc.typeArticle-
dc.contributor.collegeCollege of Dentistry (치과대학)-
dc.contributor.departmentDept. of General Dentistry (통합진료학)-
dc.contributor.googleauthor전국진-
dc.contributor.googleauthor박혁-
dc.contributor.googleauthor박창서-
dc.contributor.googleauthor김기덕-
dc.contributor.googleauthor이희철-
dc.admin.authorfalse-
dc.admin.mappingfalse-
dc.contributor.localIdA00332-
dc.relation.journalcodeJ02085-
dc.subject.keywordtomography-
dc.subject.keywordx-ray computed-
dc.subject.keywordcephalometry-
dc.subject.keywordreproducibility of results-
dc.contributor.alternativeNameKim, Kee Deog-
dc.contributor.affiliatedAuthorKim, Kee Deog-
dc.rights.accessRightsfree-
dc.citation.volume33-
dc.citation.number3-
dc.citation.startPage171-
dc.citation.endPage178-
dc.identifier.bibliographicCitationKorean Journal of Oral and Maxillofacial Radiology (대한구강악안면방사선학회지), Vol.33(3) : 171-178, 2003-
dc.identifier.rimsid52071-
dc.type.rimsART-
Appears in Collections:
2. College of Dentistry (치과대학) > Dept. of Advanced General Dentistry (통합치의학과) > 1. Journal Papers

qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.